Skip to content

Thermax · Absorption chillers

Thermax TAC E7

Multi-energy absorption chillers driven by exhaust gas and hot water

Cooling capacity
422 – 8,122 kW
Efficiency
COP: 1.01 to 1.15
Energy
Exhaust gas and hot water
Ask an engineer
Thermax TAC E7

Technical data

Key data

Cooling capacity
422 – 8,122 kW
Rating conditions
CHW 12/7 ºC
CW 32/37 ºC
Energy
Exhaust gas and hot water
Output temperature
Chilled water at 7 ºC
Refrigerant
Water (H2O)
Efficiency
COP: 1.01 to 1.15

Main advantages

  • Combined use of exhaust gas and hot water
  • Better use of the installation's energy
  • Adapts to different operating conditions
  • Lower electricity consumption
  • Integration into cogeneration and trigeneration plants

Models

Thermax TAC E7 models

Technical data from the manufacturer's data sheet.

TAC E7
Model Unit E7 C3E7 C4E7 D1E7 D2E7 D3E7 D4E7 E1E7 E2E7 E3E7 E4E7 E5E7 E6E7 F1E7 F2E7 F3E7 G1E7 G2E7 G3E7 G4E7 G5E7 G6E7 H1E7 H2E7 J1E7 J2
GENERAL DATA
Version / application Multi-energy absorption chiller (exhaust gas + hot water)
Installation location Indoor
Refrigerant / absorbent Water (R718) / Lithium bromide (LiBr)
Chilled water inlet / outlet temperature °C 12.0 / 6.0
Maximum allowable pressure, chilled water circuit bar(g) 8
Cooling water inlet temperature (tower) °C 27.0
Maximum allowable pressure, cooling water circuit bar(g) 8
CAPACITY AND HYDRAULIC CIRCUITS
Nominal cooling capacity kW 422 531 672 802 1,002 1,125 1,350 1,498 1,719 1,849 2,074 2,285 2,451 2,549 2,813 3,200 3,534 4,012 4,325 4,922 5,369 6,012 6,751 7,169 8,122
Nominal cooling capacity (reference) TR 120 151 191 228 285 320 384 426 489 526 590 650 697 725 800 910 1,005 1,141 1,230 1,400 1,527 1,710 1,920 2,039 2,310
Chilled water flow m³/h 60.1 75.8 95.8 114.4 143.1 161 193.2 214.6 246.1 264.6 296.8 326.9 350.5 364.8 402 457.7 505 573.6 618.7 703.8 768.2 859.8 965.6 1,025.7 1,161.6
Cooling water flow (tower) m³/h 115 145 186 220 275 310 375 420 480 515 580 640 680 710 780 895 990 1,120 1,210 1,370 1,495 1,680 1,880 1,990 2,270
FLUE GAS CIRCUIT (HEAT SOURCE 1)
Required heat input (exhaust gas) kW 185 224 270 343 420 471 557 620 711 759 862 948 1,043 1,078 1,183 1,324 1,458 1,659 1,789 2,045 2,263 2,537 2,823 2,918 3,332
Flue gas inlet temperature range °C 350 – 600
Flue gas outlet temperature °C 170
HOT WATER CIRCUIT (HEAT SOURCE 2)
Required heat input (hot water) kW 185 246 358 392 500 563 693 777 885 962 1,056 1,167 1,195 1,281 1,423 1,651 1,824 2,046 2,225 2,493 2,669 2,997 3,371 3,788 4,203
Hot water inlet temperature °C 90
Hot water outlet temperature °C 75
Maximum allowable pressure, hot water circuit bar(g) 8
ELECTRICAL DATA
Total electrical consumption kVA 10.1 10.1 11.2 11.2 14.8 14.8 16.9 19.1 19.1 21.3 21.3 21.3 26 26 28.2 29.6 29.6 29.6 29.6 37.5 37.5 37.5 38.5 40.7 40.7
Supply voltage / supply conditions V / Hz 415V (±10%), 50Hz (±5%), AC III + neutral
DIMENSIONS AND WEIGHTS
Length (L) mm 3,200 3,200 4,200 4,200 4,400 4,400 5,100 5,400 5,400 5,400 5,600 5,600 6,800 6,800 6,800 7,500 7,500 7,700 7,700 7,900 7,900 9,300 9,300 10,800 10,800
Width (W) mm 2,900 2,900 3,000 3,000 3,200 3,200 3,500 3,600 3,600 3,600 3,800 3,800 4,000 4,000 4,000 4,300 4,300 4,500 4,500 4,800 4,800 4,900 4,900 5,000 5,000
Height (H) mm 3,300 3,300 3,300 3,300 3,300 3,300 3,400 3,800 3,800 3,800 4,100 4,100 4,200 4,200 4,200 4,400 4,400 4,700 4,700 5,000 5,000 5,000 5,000 5,000 5,000
Operating weight kg 10,000 11,000 12,500 13,500 16,500 17,500 19,000 22,500 23,500 24,500 28,000 31,000 35,200 37,000 39,500 50,000 52,000 62,000 65,000 77,000 80,000 88,000 92,000 106,000 110,500

Downloads

Catalogues and data sheets

Is the Thermax TAC E7 range right for your project?

We'll help you choose the model and send you the technical documentation and a proposal.

Absorption chillers

Other ranges in this family

Yazaki WFC-SC

Yazaki

Yazaki WFC-SC

Hot water-driven single-effect absorption chillers

Cooling capacity
17.6 – 176 kW
Energy
Hot water
Efficiency
COP: 0.7
Thermax TAC L1

Thermax

Thermax TAC L1

Hot water-driven single-effect absorption chillers

Cooling capacity
157 – 1,000 kW
Energy
Hot water
Efficiency
COP: 0.7 to 0.8
Thermax TAC L5

Thermax

Thermax TAC L5

Hot water-driven single-effect absorption chillers

Cooling capacity
714 – 5,764 kW
Energy
Hot water
Efficiency
COP: 0.7 to 0.8
Thermax TAC S1

Thermax

Thermax TAC S1

Steam-driven single-effect absorption chillers

Cooling capacity
404 – 7,385 kW
Energy
Steam
Efficiency
COP: 0.7 to 0.8
Thermax TAC S2

Thermax

Thermax TAC S2

Steam-driven double-effect absorption chillers

Cooling capacity
400 – 7,410 kW
Energy
Steam
Efficiency
COP: 1.3 to 1.5
Thermax TAC G2

Thermax

Thermax TAC G2

Gas-fired double-effect absorption chillers

Cooling capacity
401 – 4,969 kW
Energy
Natural gas or LPG
Efficiency
COP: 1.3 to 1.5

Be the first to know

Sign up for the latest news, exclusives and offers from Absorsistem

To download the document, please enter your email address.

Thank you! Your download has started.

Something went wrong. Please try again later.

Please check the highlighted fields.