Absorption chillers

Chillers that produce chilled water from heat instead of electricity: hot water, steam, gas or exhaust gas, from 17.6 kW to over 8 MW.

Cooling capacity
17,6 – 8.122 kW
Heating capacity
21 – 105 kW
Ranges
11
Manufacturers
Yazaki, Thermax, and Robur
Absorption chillers

Technology

What are absorption chillers?

An absorption chiller (also called an absorption machine) produces chilled water for air conditioning or processes from a heat source: hot water, steam, exhaust gas or the direct firing of natural gas or LPG. In absorption cooling, the cycle replaces the electric compressor, so electricity consumption is minimal and the available waste or renewable heat is turned into cooling capacity.

Absorsistem distributes Yazaki and Thermax lithium bromide and water (LiBr-H2O) absorption chillers, and Robur GA ACF gas-fired ammonia-water (NH3-H2O) chillers. Single-effect ranges use hot water or low-pressure steam, with a COP of 0.7 to 0.8. Double-effect ranges run on higher-pressure steam, gas or exhaust gas, with a COP of 1.3 to 1.5.

Absorption

Ammonia-water (NH₃-H₂O) and lithium bromide (H₂O-LiBr) absorption thermodynamic cycles, and Type I and Type II absorption heat pumps.

How it works: Absorption

Cogeneration

The principles of cogeneration and its basic technologies, micro-generation and trigeneration explained.

How it works: Cogeneration

Ranges

absorption chillers ranges

11 ranges from Yazaki, Thermax, and Robur. Nominal data from the manufacturer's technical data sheets.

Yazaki WFC-SC

Yazaki

Yazaki WFC-SC

Hot water-driven single-effect absorption chillers

Cooling capacity
17.6 – 176 kW
Energy
Hot water
Efficiency
COP: 0.7
Thermax TAC L1

Thermax

Thermax TAC L1

Hot water-driven single-effect absorption chillers

Cooling capacity
157 – 1,000 kW
Energy
Hot water
Efficiency
COP: 0.7 to 0.8
Thermax TAC L5

Thermax

Thermax TAC L5

Hot water-driven single-effect absorption chillers

Cooling capacity
714 – 5,764 kW
Energy
Hot water
Efficiency
COP: 0.7 to 0.8
Thermax TAC S1

Thermax

Thermax TAC S1

Steam-driven single-effect absorption chillers

Cooling capacity
404 – 7,385 kW
Energy
Steam
Efficiency
COP: 0.7 to 0.8
Thermax TAC S2

Thermax

Thermax TAC S2

Steam-driven double-effect absorption chillers

Cooling capacity
400 – 7,410 kW
Energy
Steam
Efficiency
COP: 1.3 to 1.5
Thermax TAC G2

Thermax

Thermax TAC G2

Gas-fired double-effect absorption chillers

Cooling capacity
401 – 4,969 kW
Energy
Natural gas or LPG
Efficiency
COP: 1.3 to 1.5
Thermax TAC E2

Thermax

Thermax TAC E2

Exhaust gas-driven double-effect absorption chillers

Cooling capacity
432 – 8,115 kW
Energy
Exhaust gas
Efficiency
COP: 1.3 to 1.5
Thermax TAC E7

Thermax

Thermax TAC E7

Multi-energy absorption chillers driven by exhaust gas and hot water

Cooling capacity
422 – 8,122 kW
Energy
Exhaust gas and hot water
Efficiency
COP: 1.01 to 1.15
Robur GA ACF

Robur

Robur GA ACF

Gas-fired absorption chillers

Cooling capacity
17.7 – 88.5 kW
Energy
Natural gas or LPG
Efficiency
GUE 71%
Robur GA ACF HR

Robur

Robur GA ACF HR

Gas-fired absorption chillers

Cooling capacity
17.7 – 88.5 kW
Heating capacity
21 – 105 kW
Energy
Natural gas or LPG
Efficiency
GUE 155%
Robur GA ACF special versions

Robur

Robur GA ACF special versions

Gas-fired absorption chillers

Cooling capacity
17.7 – 88.5 kW
Energy
Natural gas or LPG
Efficiency
GUE 71%

Comparison

absorption chillers comparison

Nominal values from the manufacturer's technical data sheets.

Range Manufacturer Cooling capacityHeating capacityEnergyEfficiency
Yazaki WFC-SC Yazaki 17.6 – 176 kW — Hot water COP: 0.7
Thermax TAC L1 Thermax 157 – 1,000 kW — Hot water COP: 0.7 to 0.8
Thermax TAC L5 Thermax 714 – 5,764 kW — Hot water COP: 0.7 to 0.8
Thermax TAC S1 Thermax 404 – 7,385 kW — Steam COP: 0.7 to 0.8
Thermax TAC S2 Thermax 400 – 7,410 kW — Steam COP: 1.3 to 1.5
Thermax TAC G2 Thermax 401 – 4,969 kW — Natural gas or LPG COP: 1.3 to 1.5
Thermax TAC E2 Thermax 432 – 8,115 kW — Exhaust gas COP: 1.3 to 1.5
Thermax TAC E7 Thermax 422 – 8,122 kW — Exhaust gas and hot water COP: 1.01 to 1.15
Robur GA ACF Robur 17.7 – 88.5 kW — Natural gas or LPG GUE 71%
Robur GA ACF HR Robur 17.7 – 88.5 kW 21 – 105 kW Natural gas or LPG GUE 155%
Robur GA ACF special versions Robur 17.7 – 88.5 kW — Natural gas or LPG GUE 71%

The rating conditions for each capacity are given on the range's page.

Selection criteria

When to choose absorption chillers

  • Installations with waste heat available: hot water from cogeneration, process steam or engine exhaust gas
  • Cogeneration and trigeneration plants that need cooling as well as electricity and heat
  • Cooling with solar thermal energy or biomass boilers
  • Buildings and industries with limited electrical capacity, or capacity that is hard to increase
  • Processes that need low-temperature chilled water: special versions of the Robur GA ACF reach −10 ºC

Downloads

Catalogues and data sheets

Which range suits your project?

Tell us the capacity, the services you need and the energy available. We'll recommend the configuration and send you a proposal.

Be the first to know

Sign up for the latest news, exclusives and offers from Absorsistem

To download the document, please enter your email address.

Thank you! Your download has started.

Something went wrong. Please try again later.

Please check the highlighted fields.