Skip to content

IVAR · Boilers and steam generators

IVAR ASB / ASA

Superheated water generator with 3 flue gas passes

Heating capacity
140 – 2,907 kW
Efficiency
90 %
Energy
Natural gas, LPG, diesel oil
Ask an engineer
IVAR ASB / ASA

Technical data

Key data

Heating capacity
140 – 2,907 kW
Energy
Natural gas, LPG, diesel oil
Output temperature
ASB series: 158.1 ºC - 4.9 bar
ASA series: 183.2 ºC - 9.8 bar
Efficiency
90 %

Main advantages

  • Designed to the European PED Directive 2014/68/EU
  • Versions by required pressure (ASB 4.9 bar / ASA 9.8 bar)
  • Three flue gas passes and low NOx emissions

Models

IVAR ASB / ASA models

Technical data from the manufacturer's data sheet.

ASB (4.9 bar)

ASB (4.9 bar)
Model Unit 120180230320400500600800100012001500175020002500
PERFORMANCE AND HEAT OUTPUTS
Rated output [kW] kW 140 210 268 372 465 581.5 700 930 1,163 1,396 1,745 2,035 2,325 2,907
Rated output [kcal/h x1000] kcal/h x1000 120 180 230 320 400 500 602 800 1,000 1,200 1,500 1,750 2,000 2,500
Furnace output [kW] kW 157 235 300 418 523 653 784 1,046 1,307 1,568 1,960 2,287 2,613 3,267
Furnace output [kcal/h x1000] kcal/h x1000 135 202 258 360 450 561 674 900 1,124 1,348 1,685 1,967 2,247 2,809
HYDRAULIC AND COMBUSTION PARAMETERS
Combustion chamber pressure mbar 2 2.5 3 4.2 4.5 5 6 6.5 7 7 8 8.2 9 9.5
Water-side pressure drop (Δt 15°C) mbar 3.7 8 13 24 11 17 12 18 20 30 37 30 40 45
Water capacity dm³ (L) 335 410 410 780 780 875 964 1,189 1,485 1,696 2,455 2,750 3,100 4,200
Maximum operating pressure bar 4.9
PHYSICAL DIMENSIONS
Overall outside width (A) mm 950 950 950 1,140 1,140 1,210 1,210 1,350 1,350 1,460 1,640 1,740 1,780 1,890
Overall height (H) mm 1,235 1,225 1,225 1,430 1,430 1,510 1,510 1,670 1,670 1,770 1,940 2,050 2,080 2,190
Overall outside length (Lt) mm 1,550 1,970 1,970 2,280 2,280 2,350 2,550 2,635 3,135 3,060 3,400 3,400 3,600 4,200
Dimension C (width / front volume) mm 580 580 580 680 680 725 725 805 805 835 950 1,008 1,020 1,075
Distance to furnace / flue axis (f) mm 375 425 425 477 477 487 487 578 578 568 570 685 695 720
Distance between flow and return connections (i) mm 700 970 970 1,060 1,060 1,100 1,360 1,200 1,700 1,600 1,800 1,700 1,886 2,380
CONNECTIONS AND WEIGHT
Flow / return connections (r - f) DN DN 65 DN 65 DN 65 DN 80 DN 80 DN 100 DN 100 DN 125 DN 125 DN 150 DN 150 DN 200 DN 200 DN 200
Drain connection (S) DN DN 25 DN 25 DN 25 DN 25 DN 25 DN 25 DN 25 DN 25 DN 25 DN 40 DN 40 DN 40 DN 40 DN 40
Flue diameter (Camino Ø) mm 220 220 220 250 250 250 250 350 350 400 450 450 500 500
Empty weight kg 760 1,080 1,080 1,540 1,540 1,675 2,060 2,350 2,930 3,500 4,240 4,790 5,870 7,000

ASA (9.8 bar)

ASA (9.8 bar)
Model Unit 120180230320400500600800100012001500175020002500
PERFORMANCE AND HEAT OUTPUTS
Rated output [kW] kW 140 210 268 372 465 581.5 700 930 1,163 1,396 1,745 2,035 2,325 2,907
Rated output [kcal/h x1000] kcal/h x1000 120 180 230 320 400 500 602 800 1,000 1,200 1,500 1,750 2,000 2,500
Furnace output [kW] kW 157 235 300 418 523 653 784 1,046 1,307 1,568 1,960 2,287 2,613 3,267
Furnace output [kcal/h x1000] kcal/h x1000 135 202 258 360 450 561 674 900 1,124 1,348 1,685 1,967 2,247 2,809
HYDRAULIC AND COMBUSTION PARAMETERS
Combustion chamber pressure mbar 2 2.5 3 4.2 4.5 5 6 6.5 7 7 8 8.2 9 9.5
Water-side pressure drop (Δt 15°C) mbar 3.7 8 13 24 11 17 12 18 20 30 37 30 40 45
Water capacity dm³ (L) 335 410 410 780 780 875 1,020 1,189 1,485 1,696 2,455 2,750 3,100 4,200
Maximum operating pressure bar 9.8
PHYSICAL DIMENSIONS
Overall outside width (A) mm 950 950 950 1,140 1,140 1,210 1,230 1,350 1,350 1,460 1,640 1,740 1,780 1,890
Overall height (H) mm 1,235 1,225 1,225 1,430 1,430 1,510 1,530 1,670 1,670 1,770 1,940 2,020 2,080 2,190
Overall outside length (Lt) mm 1,555 1,975 1,975 2,285 2,285 2,355 2,555 2,640 3,140 3,070 3,360 3,400 3,600 4,210
Dimension C (width / front volume) mm 580 580 580 680 680 725 735 805 805 835 950 1,007 1,020 1,075
Distance to furnace / flue axis (f) mm 378 427 427 479 479 488 488 579 578 575 576 680 715 725
Distance between flow and return connections (i) mm 700 970 970 1,060 1,060 1,100 1,360 1,200 1,700 1,600 1,800 1,700 1,886 2,380
CONNECTIONS AND WEIGHT
Flow / return connections (r - f) DN DN 65 DN 65 DN 65 DN 80 DN 80 DN 100 DN 100 DN 125 DN 125 DN 150 DN 150 DN 200 DN 200 DN 200
Drain connection (S) DN DN 25 DN 25 DN 25 DN 25 DN 25 DN 25 DN 25 DN 25 DN 25 DN 40 DN 40 DN 40 DN 40 DN 40
Flue diameter (Camino Ø) mm 220 220 220 250 250 250 250 350 350 400 450 450 500 500
Empty weight kg 1,160 1,560 1,560 1,850 1,850 1,970 2,550 2,800 3,500 4,200 5,140 5,800 6,300 8,400

Downloads

Catalogues and data sheets

Is the IVAR ASB / ASA range right for your project?

We'll help you choose the model and send you the technical documentation and a proposal.

Boilers and steam generators

Other ranges in this family

IVAR SupeRAC

IVAR

IVAR SupeRAC

6 bar monobloc hot water boilers with flame reversal chamber and high efficiency

Heating capacity
94 – 4,150 kW
Energy
Natural gas, LPG, diesel oil, biogas
Efficiency
91 - 93%
IVAR SupeRAC 2F

IVAR

IVAR SupeRAC 2F

6 bar hot water boilers with twin stacked furnaces for wide modulation and redundancy

Heating capacity
186 – 814 kW
Energy
Natural gas, LPG, diesel oil, biogas
Efficiency
91 - 93%
IVAR SupeRAC AR

IVAR

IVAR SupeRAC AR

High-efficiency hot water boilers with 3 flue gas passes and low NOx

Heating capacity
81 – 3,610 kW
Energy
Natural gas, LPG, diesel oil, biogas
Efficiency
96.8 to 98.0%
IVAR ECOCOND

IVAR

IVAR ECOCOND

Very high-efficiency AISI 316L stainless steel condensing boilers for low temperatures

Heating capacity
110 – 641 kW
Energy
Natural gas, LPG, diesel oil
Efficiency
95.2 to 98.1%
IVAR TRINOX

IVAR

IVAR TRINOX

Large industrial boilers with 3 true flue gas passes and low NOx

Heating capacity
1,165 – 10,560 kW
Energy
Natural gas, LPG, diesel oil
Efficiency
94 %
IVAR ODE/C

IVAR

IVAR ODE/C

Thermal oil boilers for high-temperature processes

Heating capacity
116 – 5,815 kW
Energy
Natural gas, LPG, diesel oil
Efficiency
87 %

Be the first to know

Sign up for the latest news, exclusives and offers from Absorsistem

To download the document, please enter your email address.

Thank you! Your download has started.

Something went wrong. Please try again later.

Please check the highlighted fields.