Skip to content

Enerblue · High-efficiency chillers with natural refrigerant

Enerblue PURPLE

High-efficiency air-to-water chillers for industrial processes, with on/off compressors and natural refrigerant

Cooling capacity
30.7 – 291 kW
Heating capacity
(up to 88 kW in DS version)
Efficiency
EER: 2.7 to 3.1
SEPR: 2.8 to 3.9
Energy
Electricity
Ask an engineer
Enerblue PURPLE

Technical data

Key data

Cooling capacity
30.7 – 291 kW
Heating capacity
(up to 88 kW in DS version)
Rating conditions
A35;W7
Energy
Electricity
Output temperature
from +20 ºC to -8 ºC
Refrigerant
R290 (propane)
Efficiency
EER: 2.7 to 3.1
SEPR: 2.8 to 3.9
Energy class
ErP Ecodesign compliant

Main advantages

  • Specifically designed for industrial process cooling
  • Very robust semi-hermetic reciprocating compressors
  • Isolated compressor enclosure with ATEX extractor and R290 leak detector
  • Optional heat recovery unit
  • Available with an integrated hydronic kit

Models

Enerblue PURPLE models

Technical data from the manufacturer's data sheet.

PURPLE (12.1 to 50.1)

PURPLE (12.1 to 50.1)
Model Unit 12.115.120.122.125.130.132.134.135.140.145.150.1
COOLING (EN 14511 VALUES) (A35; W12/7°C)
Nominal cooling capacity (1) kW 30.7 35.9 40.6 42.3 49.8 56.3 60.6 66.7 71 86.6 91 99.9
Total power input in cooling (1) kW 10.2 12.4 14.1 14.6 17.3 20.4 22.8 23.1 24.2 28.4 30.6 33.9
EER (1) 3 2.9 2.9 2.9 2.7 2.9 2.9 2.8 2.9 3 3 2.9
LOW-TEMPERATURE COOLING (EN 14511) (A35; W-2/-8°C) (30% glycol)
Nominal cooling capacity (-8°C) (2) kW 19.2 22.4 25.6 26.5 31.3 35.6 38.1 41.1 44.3 54 56.6 62.2
Total power input (-8°C) (2) kW 8.6 10.2 11.2 11.7 13.7 15.8 17.7 18.2 18.9 22.9 24.6 27.3
EER (-8°C) (2) 2.2 2.2 2.3 2.3 2.3 2.3 2.2 2.3 2.3 2.4 2.3 2.3
SEPR (low-temp. process) (2) 3.63 3.6 3.5 3.6 3.3 3.4 3.6 3.3 3.5 3.8 3.7 3.7
COMPRESSOR AND REFRIGERANT (R290)
Compressor type Semi-hermetic reciprocating
No. of compressors / circuits No. / No. 1 / 1
Capacity steps No. 1
R290 charge per circuit kg 1.5 1.5 1.7 1.7 1.9 2.9 3.5 3.5 3.5 4.4 4.4 4.5
AC AXIAL FANS AND USER-SIDE HEAT EXCHANGER
Fan type AC axial
No. of fans No. 1 1 1 1 1 1 1 1 1 2 2 2
Fan power input kW 1.4 1.4 1.6 1.6 1.6 1.4 1.6 1.6 1.4 2.8 2.6 2.8
Total air flow m³/h 15,050 14,993 16,500 16,709 17,125 17,159 17,232 20,379 20,354 38,082 34,880 37,908
User heat exchanger type Single-circuit plate
User water flow (A35; W12/7) (1) l/h 5,298 6,189 7,000 7,293 8,578 9,702 10,440 11,510 12,230 14,940 15,690 17,220
Water pressure drop (1) kPa 38 50 42 45 45 47 45 45 45 53 48 46
DESUPERHEATER (20% DS PARTIAL RECOVERY - OPTIONAL)
DS heat exchanger type Plate
DS nominal heat output (3) kW 6.8 8.7 9.8 10.2 12.5 14.8 17.1 15.8 19.6 19.3 21.6 23.7
DS water flow (W40/45°C) (3) l/h 1,171 1,496 1,687 1,753 2,150 2,546 2,936 2,721 3,371 3,318 3,720 4,078
DS water pressure drop (3) kPa 3 4 5 5 10 11 13 11 7 8 9 11
HYDRAULIC MODULE, ACOUSTIC DATA (LN) AND DIMENSIONS
Available pump pressure kPa 184.9 159.5 153.5 145 139.6 139.6 152.4 134.5 131.3 158.7 158.2 150.2
Pump power input kW 1.3 1.3 1.3 1.3 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7
Buffer tank capacity l 130 130 130 130 130 130 130 250 250 250 250 250
User hydraulic connections inches 1"1/2 1"1/2 1"1/2 1"1/2 1"1/2 1"1/2 2" 2" 2" 2" 2" 2"
Sound power level LN (4) dB(A) 75 76 76 77 85 85 85 85 85 87 87 87
Sound pressure level at 1 m LN (5) dB(A) 58 59 59 60 67 67 67 67 67 69 69 69
Length / width / height mm 1940 / 850 / 2000 1940 / 850 / 2000 1940 / 850 / 2000 1940 / 850 / 2000 1874 / 850 / 2388 1874 / 1212 / 2388 1940 / 1212 / 2000 1874 / 1212 / 2388 1874 / 1212 / 2388 2888 / 1210 / 2388 2888 / 1210 / 2388 2888 / 1210 / 2388
Shipping weight kg 617 623 632 684 702 772 764 775 828 1,038 1,045 1,059
  • Notes and reference conditions (Enerblue PURPLE technical catalogue - p. 7):
  • (1) Performance in accordance with EN 14511: outdoor air temp. 35 °C; evaporator water inlet/outlet temp. 12/7 °C.
  • (2) Performance in accordance with EN 14511-2018 and EU 2015/1095 for an average climate (Strasbourg); water application: -8 °C, 30 % ethylene glycol.
  • (3) Water inlet/outlet temp.: evaporator 12/7 °C; desuperheater 40/45 °C.
  • (4) Lw: free-field sound power values calculated in accordance with ISO 3744. Operating conditions (A35; W7 °C).
  • (5) Sound pressure values measured at 1 m in free field in accordance with ISO 3744. Operating conditions (A35; W7 °C).

PURPLE (55.1 to 80.2)

PURPLE (55.1 to 80.2)
Model Unit 55.160.175.135.240.245.250.255.260.275.280.2
COOLING (EN 14511 VALUES) (A35; W12/7°C)
Nominal cooling capacity (1) kW 109 122 131.4 145.8 173.7 182.9 200.1 218.8 241.8 262.9 291.3
Total power input in cooling (1) kW 39.4 44.8 48.8 49.9 56.5 60.9 67.5 78.5 89.3 97.2 106.5
EER (1) 2.8 2.7 2.7 2.9 3.1 3 3 2.8 2.7 2.7 2.7
LOW-TEMPERATURE COOLING (EN 14511) (A35; W-2/-8°C) (30% glycol)
Nominal cooling capacity (-8°C) (2) kW 67.1 73.8 78.5 92.3 108.8 114.1 125.3 135.3 147.1 157.8 177
Total power input (-8°C) (2) kW 32.4 35.4 39.3 39.2 45.9 49.4 54.6 64.9 70.8 78.8 86.5
EER (-8°C) (2) 2.1 2.1 2 2.4 2.4 2.3 2.3 2.1 2.1 2 2
SEPR (low-temp. process) (2) 2.9 3 2.9 3.6 3.9 3.8 3.7 2.9 3 2.9 2.8
COMPRESSOR AND REFRIGERANT (R290)
Compressor type Semi-hermetic reciprocating
No. of compressors / circuits No. / No. 1 / 1 1 / 1 1 / 1 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2
Capacity steps No. 1 1 1 2 2 2 2 2 2 2 2
R290 charge per circuit kg 5.2 5.2 7.6 9.4 9.4 10 10.4 10.4 10.6 11 11
AC AXIAL FANS AND USER-SIDE HEAT EXCHANGER
Fan type AC axial
No. of fans No. 2 2 2 2 4 4 4 4 4 4 4
Fan power input kW 3 2.9 2.9 3 5.6 5.1 5.5 5.9 5.9 5.9 5.8
Total air flow m³/h 40,440 40,293 40,158 40,039 76,148 69,715 75,815 80,874 80,574 80,358 79,854
User heat exchanger type Single-circuit plate Single-circuit plate Single-circuit plate Dual-circuit plate Dual-circuit plate Dual-circuit plate Dual-circuit plate Dual-circuit plate Dual-circuit plate Dual-circuit plate Dual-circuit plate
User water flow (A35; W12/7) (1) l/h 18,780 21,020 22,650 25,090 29,910 31,490 34,450 37,660 41,600 45,250 50,120
Water pressure drop (1) kPa 47 46 45 24 33 32 33 34 35 35 45
DESUPERHEATER (20% DS PARTIAL RECOVERY - OPTIONAL)
DS heat exchanger type Plate
DS nominal heat output (3) kW 29.4 34.4 38.1 40.5 38.5 43.3 47.4 50.5 67.7 76.1 87.6
DS water flow (W40/45°C) (3) l/h 5,064 5,917 6,553 6,959 6,622 7,448 8,153 8,684 11,645 13,096 15,059
DS water pressure drop (3) kPa 11 14 15 12 7.4 9 10.6 11.6 14.5 14.7 14.7
HYDRAULIC MODULE, ACOUSTIC DATA (LN) AND DIMENSIONS
Available pump pressure kPa 159 152.1 144.9 183.8 164 161.9 153.4 142.9 128.4 153.2 136.3
Pump power input kW 2.5 2.5 2.5 3 3 3 3 3 3 4 4
Buffer tank capacity l 250 250 250 250 450 450 450 450 450 450 450
User hydraulic connections inches 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 2"1/2 3" 3" 3"
Sound power level LN (4) dB(A) 87 89 89 89 91 91 91 91 93 93 93
Sound pressure level at 1 m LN (5) dB(A) 69 71 71 71 71 71 71 71 73 73 73
Length / width / height mm 2888 / 1210 / 2388 2888 / 1210 / 2388 2888 / 1210 / 2388 2877 / 1214 / 2388 5320 / 1214 / 2388 5320 / 1214 / 2388 5320 / 1214 / 2388 5320 / 1214 / 2388 5320 / 1214 / 2388 5320 / 1214 / 2388 5320 / 1214 / 2388
Shipping weight kg 1,140 1,155 1,169 1,276 1,832 1,844 1,848 2,004 2,032 2,066 2,082
  • Notes and reference conditions (Enerblue PURPLE technical catalogue - p. 8):
  • (1) Performance in accordance with EN 14511: outdoor air temp. 35 °C; evaporator water inlet/outlet temp. 12/7 °C.
  • (2) Performance in accordance with EN 14511-2018 and EU 2015/1095 for an average climate (Strasbourg); water application: -8 °C, 30 % ethylene glycol.
  • (3) Water inlet/outlet temp.: evaporator 12/7 °C; desuperheater 40/45 °C.
  • (4) Lw: free-field sound power values calculated in accordance with ISO 3744. Operating conditions (A35; W7 °C).
  • (5) Sound pressure values measured at 1 m in free field in accordance with ISO 3744. Operating conditions (A35; W7 °C).

Downloads

Catalogues and data sheets

Is the Enerblue PURPLE range right for your project?

We'll help you choose the model and send you the technical documentation and a proposal.

High-efficiency chillers with natural refrigerant

Other ranges in this family

Enerblue SILVER

Enerblue

Enerblue SILVER

Water chillers with inverter screw compressors and natural refrigerant

Cooling capacity
308 – 768 kW
Heating capacity
(up to 200 kW in DS version)
Energy
Electricity
Efficiency
EER: 2.8 to 3.1
SEER: 4.3 to 4.6
Enerblue PURPLEi

Enerblue

Enerblue PURPLEi

High-efficiency air-to-water chillers with inverter compressors, EC fans and natural refrigerant

Cooling capacity
30.5 – 291 kW
Heating capacity
(up to 73 kW in DS version)
Energy
Electricity
Efficiency
EER: 2.8 to 3.1
SEER: 4.1 to 4.4
Enerblue PURPLE FC

Enerblue

Enerblue PURPLE FC

Air-to-water chillers with free cooling, on/off compressors and natural refrigerant

Cooling capacity
54 – 146 kW
Heating capacity
(up to 34 kW in DS version)
Energy
Electricity
Efficiency
EER: 2.7 to 2.8