IVAR
IVAR SupeRAC
6 bar monobloc hot water boilers with flame reversal chamber and high efficiency
- Heating capacity
- 94 – 4,150 kW
- Energy
- Natural gas, LPG, diesel oil, biogas
- Efficiency
- 91 - 93%
IVAR · Boilers and steam generators
High-efficiency hot water boilers with 3 flue gas passes and low NOx
Technical data
Models
Technical data from the manufacturer's data sheet.
| Model | Unit | 80 | 90 | 130 | 170 | 200 | 250 | 300 | 350 | 400 | 450 | 500 | 600 | 700 | 800 | 900 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PERFORMANCE AND HEAT OUTPUTS | ||||||||||||||||
| Nominal useful output (kW) | kW | 81 | 91 | 132 | 170 | 203 | 253 | 304 | 354 | 398 | 455 | 505 | 610 | 715 | 820 | 920 |
| Nominal useful output (kcal/h x1000) | kcal/h x1000 | 69.66 | 78.26 | 113.5 | 146.2 | 174.6 | 217.6 | 261.4 | 304.4 | 342.3 | 391.3 | 434.3 | 524.6 | 614.9 | 705.2 | 791.2 |
| Furnace heat input (kW) | kW | 86.2 | 96.7 | 140 | 179.6 | 214 | 266 | 320 | 372 | 418 | 477 | 530 | 640 | 750 | 860 | 966 |
| Furnace heat input (kcal/h x1000) | kcal/h x1000 | 74.13 | 83.16 | 120.4 | 154.5 | 184 | 228.8 | 275.2 | 319.9 | 359.5 | 410.2 | 455.8 | 550.4 | 645 | 739.6 | 830.8 |
| HYDRAULIC AND COMBUSTION PARAMETERS | ||||||||||||||||
| Furnace back pressure | mbar | 0.4 | 0.5 | 0.9 | 0.9 | 1.2 | 1.8 | 2.5 | 3.3 | 2.7 | 3.2 | 3.7 | 3.6 | 4.5 | 4.4 | 4.8 |
| Water-side pressure drop (Δt 15°C) | mbar | 3.4 | 4.3 | 9 | 5.5 | 7 | 13 | 18 | 23 | 13 | 17 | 21 | 13 | 19 | 25 | 32 |
| Water capacity | dm³ (L) | 119 | 119 | 155 | 228 | 228 | 285 | 276 | 329 | 402 | 402 | 476 | 697 | 795 | 733 | 817 |
| Maximum standard pressure (8-10 bar on request) | bar | 5 | 5 | 5 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
| PHYSICAL DIMENSIONS | ||||||||||||||||
| Overall outside width (A) | mm | 790 | 790 | 790 | 940 | 940 | 940 | 940 | 940 | 1,040 | 1,040 | 1,040 | 1,240 | 1,240 | 1,240 | 1,240 |
| Overall outside length (B) | mm | 1,110 | 1,110 | 1,360 | 1,405 | 1,405 | 1,655 | 1,655 | 1,905 | 1,990 | 1,990 | 2,290 | 2,345 | 2,545 | 2,545 | 2,795 |
| Overall height (H) | mm | 880 | 880 | 880 | 990 | 990 | 990 | 990 | 990 | 1,150 | 1,150 | 1,150 | 1,280 | 1,280 | 1,280 | 1,280 |
| Body width (A1) | mm | 750 | 750 | 750 | 900 | 900 | 900 | 900 | 900 | 1,000 | 1,000 | 1,000 | 1,200 | 1,200 | 1,200 | 1,200 |
| Body length (B1) | mm | 760 | 760 | 1,010 | 1,010 | 1,010 | 1,260 | 1,260 | 1,510 | 1,512 | 1,512 | 1,812 | 1,814 | 2,014 | 2,014 | 2,264 |
| Height to flue axis (d) | mm | 460 | 460 | 460 | 510 | 510 | 510 | 510 | 510 | 595 | 595 | 595 | 640 | 640 | 640 | 640 |
| Front to return connection distance (e) | mm | 430 | 430 | 430 | 465 | 465 | 465 | 465 | 465 | 625 | 625 | 625 | 625 | 625 | 625 | 625 |
| Distance between flow and return (f) | mm | 260 | 260 | 510 | 450 | 450 | 700 | 700 | 950 | 792 | 792 | 1,092 | 974 | 1,174 | 1,174 | 1,424 |
| CONNECTIONS AND WEIGHT | ||||||||||||||||
| Flow / return connections (r / f) | DN / inch | 2" | 2" | 2" | DN 65 | DN 65 | DN 65 | DN 65 | DN 65 | DN 80 | DN 80 | DN 80 | DN 100 | DN 100 | DN 100 | DN 100 |
| Expansion vessel connection (v) | DN / inch | 1"1/4 | 1"1/4 | 1"1/4 | 1"1/2 | 1"1/2 | 1"1/2 | 1"1/2 | 1"1/2 | 2" | 2" | 2" | DN 65 | DN 65 | DN 65 | DN 65 |
| Drain connection (s) | in | 3/4" | ||||||||||||||
| Flue outlet diameter (Ø) | mm | 200 | 200 | 200 | 220 | 220 | 220 | 220 | 220 | 250 | 250 | 250 | 350 | 350 | 350 | 350 |
| Empty weight | kg | 250 | 270 | 310 | 460 | 480 | 540 | 550 | 610 | 870 | 890 | 940 | 1,310 | 1,380 | 1,440 | 1,620 |
| Model | Unit | 1100 | 1300 | 1640 | 1850 | 2050 | 2580 | 3100 | 3600 |
|---|---|---|---|---|---|---|---|---|---|
| PERFORMANCE AND HEAT OUTPUTS | |||||||||
| Nominal useful output (kW) | kW | 1,100 | 1,300 | 1,645 | 1,850 | 2,050 | 2,580 | 3,100 | 3,610 |
| Nominal useful output (kcal/h x1000) | kcal/h x1000 | 946 | 1,118 | 1,414.7 | 1,591 | 1,763 | 2,218.8 | 2,666 | 3,104.6 |
| Furnace heat input (kW) | kW | 1,155 | 1,365 | 1,727 | 1,942 | 2,153 | 2,709 | 3,255 | 3,791 |
| Furnace heat input (kcal/h x1000) | kcal/h x1000 | 993.3 | 1,173.9 | 1,485.2 | 1,670.1 | 1,851.6 | 2,329.7 | 2,799.3 | 3,260.2 |
| HYDRAULIC AND COMBUSTION PARAMETERS | |||||||||
| Furnace back pressure | mbar | 5.4 | 5.6 | 5.8 | 6 | 6.5 | 6.8 | 7.5 | 8.4 |
| Water-side pressure drop (Δt 15°C) | mbar | 29 | 40 | 33 | 40 | 45 | 50 | 70 | 92 |
| Water capacity | dm³ (L) | 1,277 | 1,372 | 2,010 | 2,125 | 2,163 | 3,155 | 3,292 | 4,839 |
| Maximum standard pressure (8-10 bar on request) | bar | 6 | |||||||
| PHYSICAL DIMENSIONS | |||||||||
| Overall outside width (A) | mm | 1,380 | 1,380 | 1,610 | 1,610 | 1,610 | 1,800 | 1,800 | 2,000 |
| Overall outside length (B) | mm | 2,950 | 3,200 | 3,245 | 3,535 | 3,535 | 3,955 | 4,255 | 4,790 |
| Overall height (H) | mm | 1,500 | 1,500 | 1,800 | 1,800 | 1,800 | 2,000 | 2,000 | 2,210 |
| Body width (A1) | mm | 1,380 | 1,380 | 1,610 | 1,610 | 1,610 | 1,800 | 1,800 | 2,000 |
| Body length (B1) | mm | 2,416 | 2,666 | 2,680 | 2,970 | 2,970 | 3,320 | 3,620 | 4,024 |
| Height to flue axis (d) | mm | 810 | 810 | 965 | 965 | 965 | 1,070 | 1,070 | 1,700 |
| Front to return connection distance (e) | mm | 430 | 430 | 430 | 430 | 430 | 510 | 510 | 522 |
| Distance between flow and return (f) | mm | 1,700 | 1,950 | 1,440 | 1,730 | 1,730 | 1,700 | 2,000 | 2,200 |
| CONNECTIONS AND WEIGHT | |||||||||
| Flow / return connections (r / f) | DN | DN 125 | DN 125 | DN 150 | DN 150 | DN 150 | DN 200 | DN 200 | DN 200 |
| Expansion vessel connection (v) | DN | DN 80 | DN 80 | DN 100 | DN 100 | DN 100 | DN 125 | DN 125 | DN 125 |
| Drain connection (s) | in | 1"1/2 | |||||||
| Flue outlet diameter (Ø) | mm | 400 | 400 | 450 | 450 | 450 | 500 | 500 | 600 |
| Empty weight | kg | 2,200 | 2,580 | 3,300 | 3,640 | 3,710 | 5,140 | 5,480 | 7,490 |
Downloads
We'll help you choose the model and send you the technical documentation and a proposal.
Boilers and steam generators
IVAR
6 bar monobloc hot water boilers with flame reversal chamber and high efficiency
IVAR
6 bar hot water boilers with twin stacked furnaces for wide modulation and redundancy
IVAR
Very high-efficiency AISI 316L stainless steel condensing boilers for low temperatures
IVAR
Large industrial boilers with 3 true flue gas passes and low NOx
IVAR
Superheated water generator with 3 flue gas passes
IVAR
Thermal oil boilers for high-temperature processes