Skip to content

IVAR · Boilers and steam generators

IVAR SupeRAC 2F

6 bar hot water boilers with twin stacked furnaces for wide modulation and redundancy

Heating capacity
186 – 814 kW
Efficiency
91 - 93%
Energy
Natural gas, LPG, diesel oil, biogas
Ask an engineer
IVAR SupeRAC 2F

Technical data

Key data

Heating capacity
186 – 814 kW
Energy
Natural gas, LPG, diesel oil, biogas
Output temperature
Up to 110 ºC
Efficiency
91 - 93%

Main advantages

  • Compact design with twin stacked furnaces
  • High flexibility with independent burners
  • Optimum part-load efficiency

Models

IVAR SupeRAC 2F models

Technical data from the manufacturer's data sheet.

SupeRAC-2F (93-405)
Model Unit 93105150190230290345405
PERFORMANCE AND HEAT OUTPUTS
Nominal useful output (kW) kW 186 209.4 302.4 384 466 582 698 814
Furnace heat input (kW) kW 206 231 334 422 514 640 768 898
HYDRAULIC AND COMBUSTION PARAMETERS
Furnace back pressure mbar 0.5 0.7 1.2 1.2 1.5 2.3 3.3 4.4
Boiler water-side pressure drop (Δt 15°C) mbar 4.5 5.6 11.8 6.9 10 16.3 23 31
Water capacity dm³ (L) 238 238 310 456 456 570 552 658
Maximum standard pressure (8-10 bar on request) bar 5 5 5 6 6 6 6 6
PHYSICAL DIMENSIONS
Overall outside width (A) mm 790 790 790 940 940 940 940 940
Overall outside length (B) mm 1,110 1,110 1,360 1,405 1,405 1,655 1,655 1,905
Overall height (H) mm 1,730 1,730 1,730 1,950 1,950 1,950 1,950 1,950
Body width (A1) mm 750 750 750 900 900 900 900 900
Body length (B1) mm 760 760 1,010 1,010 1,010 1,260 1,260 1,510
Upper header axis height (h) mm 896 896 896 1,005 1,005 1,005 1,005 1,005
Height to flue axis (d) mm 850 850 850 960 960 960 960 960
Front to return connection distance (e) mm 460 460 460 510 510 510 510 510
Distance between flow and return (f) mm 430 430 430 465 465 465 465 465
Distance between flow/return connections (g) mm 260 260 510 450 450 700 700 950
Additional mounting clearance (c) mm 480 480 480 580 580 580 580 580
CONNECTIONS AND WEIGHT
Flow / return connections (r / f) DN / inch 2" 2" 2" DN 65 DN 65 DN 65 DN 65 DN 65
Expansion vessel connection (v) DN / inch 1"1/4 1"1/4 1"1/4 1"1/2 1"1/2 1"1/2 1"1/2 1"1/2
Drain connection (s) in 3/4"
Flue outlet diameter (Ø) mm 200 200 200 220 220 220 220 220
Empty weight kg 500 540 620 920 960 1,080 1,100 1,220

Downloads

Catalogues and data sheets

Is the IVAR SupeRAC 2F range right for your project?

We'll help you choose the model and send you the technical documentation and a proposal.

Boilers and steam generators

Other ranges in this family

IVAR SupeRAC

IVAR

IVAR SupeRAC

6 bar monobloc hot water boilers with flame reversal chamber and high efficiency

Heating capacity
94 – 4,150 kW
Energy
Natural gas, LPG, diesel oil, biogas
Efficiency
91 - 93%
IVAR SupeRAC AR

IVAR

IVAR SupeRAC AR

High-efficiency hot water boilers with 3 flue gas passes and low NOx

Heating capacity
81 – 3,610 kW
Energy
Natural gas, LPG, diesel oil, biogas
Efficiency
96.8 to 98.0%
IVAR ECOCOND

IVAR

IVAR ECOCOND

Very high-efficiency AISI 316L stainless steel condensing boilers for low temperatures

Heating capacity
110 – 641 kW
Energy
Natural gas, LPG, diesel oil
Efficiency
95.2 to 98.1%
IVAR TRINOX

IVAR

IVAR TRINOX

Large industrial boilers with 3 true flue gas passes and low NOx

Heating capacity
1,165 – 10,560 kW
Energy
Natural gas, LPG, diesel oil
Efficiency
94 %
IVAR ASB / ASA

IVAR

IVAR ASB / ASA

Superheated water generator with 3 flue gas passes

Heating capacity
140 – 2,907 kW
Energy
Natural gas, LPG, diesel oil
Efficiency
90 %
IVAR ODE/C

IVAR

IVAR ODE/C

Thermal oil boilers for high-temperature processes

Heating capacity
116 – 5,815 kW
Energy
Natural gas, LPG, diesel oil
Efficiency
87 %

Be the first to know

Sign up for the latest news, exclusives and offers from Absorsistem

To download the document, please enter your email address.

Thank you! Your download has started.

Something went wrong. Please try again later.

Please check the highlighted fields.