Skip to content

Enerblue · Air-source heat pumps with natural refrigerant

Enerblue PURPLEi HP

Modulating reversible air-to-water heat pumps with inverter technology and R290

Cooling capacity
22 – 181 kW
Heating capacity
26 – 221 kW
Efficiency
SCOP: 3.33 to 4.38
SEER: 3.12 to 4.21
Energy
Electricity (air-source)
Ask an engineer
Enerblue PURPLEi HP

Technical data

Key data

Cooling capacity
22 – 181 kW
Heating capacity
26 – 221 kW
Rating conditions
Heating A7;W45 · Cooling A35;W7
Energy
Electricity (air-source)
Output temperature
Maximum water temperature: 62 ºC
Refrigerant
R290 (propane)
Efficiency
SCOP: 3.33 to 4.38
SEER: 3.12 to 4.21
Energy class
A+++

Main advantages

  • Semi-hermetic inverter compressor for load modulation (down to 25 % minimum load)
  • Maximum seasonal efficiency at part load (SCOP LT up to 4.38 and SEER up to 4.21)
  • Optimised mixed twin-compressor configuration (1 inverter + 1 on/off)
  • ATEX safety enclosure with extractor and leak detector as standard

Models

Enerblue PURPLEi HP models

Technical data from the manufacturer's data sheet.

PURPLEi HP (1 compressor)

PURPLEi HP (1 compressor)
Model Unit 8.110.112.115.120.122.125.130.132.135.140.150.1
HEATING (EN14511 VALUES) (A7;W45)
Nominal heat output (1), (7) kW 26.9 30.8 35 39 43 50 59.5 62.4 74.9 86.4 95.5 109.7
Total power input in heating (1), (2), (7) kW 8 9.2 10.4 11.4 12.2 14.4 17.2 17.5 22.3 25.5 27.4 32.6
COP (1), (7) 3.33 3.34 3.55 3.59 3.66 3.64 3.63 3.67 3.36 3.39 3.48 3.36
SEASONAL HEATING EFFICIENCY (AC FANS)
SCOP LT (water 35°C) (11) 3.39 3.35 3.42 3.43 3.56 3.53 3.54 3.67 3.4 3.39 3.33 3.4
Seasonal efficiency ηsh LT (11) % 132.5 131.1 133.8 134.2 139.3 138.8 138 143.8 133.1 132.4 130.3 132.8
LT efficiency class (11) A+
SCOP MT (water 55°C) (8) 2.85 2.85 2.88 2.9 2.95 2.94 2.93 3.02 2.84 2.84 2.84 2.84
Seasonal efficiency ηsh MT (8) % 111 111 112.2 113 115 114.6 114.2 117.8 110 110.5 110 110
MT efficiency class (8) A+
COOLING (EN14511 VALUES) (A35;W7) (AC FANS)
Nominal cooling capacity (3), (7) kW 21.5 25.8 28.7 32.3 34.7 42 47.1 63.2 49.9 73.5 76.5 90.2
Total power input in cooling (3), (2), (7) kW 7.6 9.2 10.1 11.3 11.7 14 17.2 21.5 17.9 25.4 28.2 35.1
EER (3), (7) 2.81 2.81 2.84 2.86 2.98 3 2.74 2.94 2.79 2.89 2.72 2.57
SEER (10) 3.47 3.35 3.3 3.41 3.65 3.55 3.57 3.72 3.79 3.6 3.43 3.42
Seasonal efficiency ηsc (10) % 136 131 129 133 143 139 140 149 146 141 134 134
SEASONAL HEATING EFFICIENCY (EC FANS)
SCOP LT (water 35°C) (11) 3.82 3.77 3.82 3.83 4.08 4.15 4.04 4.38 3.98 3.98 3.83 3.91
Seasonal efficiency ηsh LT (11) % 150 148 150 150 160 159 163 172 156 156 150 154
LT efficiency class (11) A+ A+ A+ A++ A++ A++ A++ A++ A++ A++ A++ A++
SCOP MT (water 55°C) (8) 3.2 3.2 3.22 3.24 3.35 3.44 3.33 3.58 3.3 3.3 3.25 3.25
Seasonal efficiency ηsh MT (8) % 125 125 126 126 131 130 135 140 129 129 127 127
MT efficiency class (8) A++
COOLING (EN14511 VALUES) (A35;W7) (EC FANS)
SEER (10) 4.02 3.81 3.77 3.85 4.06 3.88 3.88 4.06 4.13 3.97 3.75 3.64
Seasonal efficiency ηsc (10) % 158 149 148 151 159 152 152 159 162 156 147 143
COMPRESSOR AND REFRIGERANT (INVERTER TECHNOLOGY)
Compressor type Reciprocating Inverter
No. of compressors / circuits No. / No. 1 / 1
Control / capacity steps (%) % 50-100
Oil charge per circuit kg 1.6 1.6 2.9 2.9 2.9 4 4 4 4 3.7 7.2 7.2
Refrigerant charge (R290) per circuit kg 2.4 2.6 2.8 2.8 3.6 3.8 4.7 5 6.1 6.1 8.5 8.5
  • Notes and reference conditions (Enerblue PURPLEi HP technical catalogue):
  • (1) Outdoor air temperature 7 °C DB, 6 °C WB; water inlet-outlet temperature 40-45 °C.
  • (2) Total power input is the sum of compressors, fans and pump, in accordance with EN 14511.
  • (3) Outdoor air temperature 35 °C; water inlet-outlet temperature 12-7 °C.
  • (4) Sound power levels calculated in accordance with ISO 3744.
  • (5) Sound pressure levels at 1 m from the unit in free field.
  • (6) Sound levels at chiller operating conditions, water 12°/7 °C, outdoor air 35 °C.
  • (7) Values calculated in accordance with EN 14511.
  • (8) In accordance with European Regulation No 813/2013 and EN14511-EN14825 for an average climate (Strasbourg); application: medium temperature (55 °C), variable outlet.
  • (9) Not subject to EU Regulation No 811/2013, rated heat output > 70 kW.
  • (10) Performance in accordance with EN14511-EN14825 for an average climate (Strasbourg); application: fan coil (W7), variable outlet temperature.
  • (11) In accordance with European standard EN14511-EN14825 for an average climate (Strasbourg); application: low temperature (35 °C), variable outlet temperature.

PURPLEi HP (2 compressors)

PURPLEi HP (2 compressors)
Model Unit 15.220.222.225.230.232.235.240.250.2
HEATING (EN14511 VALUES) (A7;W45)
Nominal heat output (1), (7) kW 84.6 91.8 99.8 117.7 136.8 144.2 163.3 184.8 220.6
Total power input in heating (1), (2), (7) kW 24.2 25.8 28.1 33.4 38.2 40.1 45.6 52.4 64.4
COP (1), (7) 3.63 3.65 3.68 3.64 3.66 3.59 3.59 3.53 3.42
SEASONAL HEATING EFFICIENCY (AC FANS)
SCOP LT (water 35°C) (8) 3.66 3.82 3.88 3.82 3.83 3.59 3.61 3.53 3.53
Seasonal efficiency ηsh LT (8) % 143.3 149.8 152.3 149.6 150.3 140.7 141.2 138.4 138.3
LT efficiency class (8) A+ A+ A++ A+ A++ A+ A+ A+ A+
SCOP MT (water 55°C) (8) 3.08 3.2 3.22 3.2 3.21 3.01 3.07 2.99 2.98
Seasonal efficiency ηsh MT (8) % 120.2 125 125.8 125 125.4 117.4 120 116.6 116
MT efficiency class (8) A+ A++ A++ A++ (9) A++ (9) A+ (9) A+ (9) A+ (9) A+ (9)
COOLING (EN14511 VALUES) (A35;W7) (AC FANS)
Nominal cooling capacity (3), (7) kW 70.5 73.5 82.8 94.7 110 116.3 133.3 148 176.6
Total power input in cooling (3), (2), (7) kW 22.6 24.4 28.1 33.4 39.9 42.2 49.6 59.4 75.8
EER (3), (7) 3.12 3.01 2.95 2.84 2.76 2.75 2.69 2.49 2.33
SEER (10) 3.83 3.85 3.84 3.84 3.84 3.48 3.47 3.27 3.12
Seasonal efficiency ηsc (10) % 150.2 151 150.6 150.6 150.6 136.2 135.8 127.8 121.8
SEASONAL HEATING EFFICIENCY (EC FANS)
SCOP LT (water 35°C) (11) 4.07 4.17 4.22 4.29 4.36 3.92 3.92 3.81 3.79
Seasonal efficiency ηsh LT (11) % 160 164 166 169 171 154 154 150 149
LT efficiency class (11) A++ A++ A++ A++ A++ A++ A++ A+ A+
SCOP MT (water 55°C) (8) 3.4 3.47 3.5 3.58 3.63 3.26 3.31 3.21 3.2
Seasonal efficiency ηsh MT (8) % 133 136 137 140 142 128 129 126 125
MT efficiency class (8) A++
COOLING (EN14511 VALUES) (A35;W7) (EC FANS)
SEER (10) 4.21 4.21 4.14 4.16 4 3.73 3.63 3.4 3.22
Seasonal efficiency ηsc (10) % 165 165 163 163 157 146 142 133 126
COMPRESSOR AND REFRIGERANT (1 INVERTER + 1 ON/OFF)
Compressor type Reciprocating (1 Inv + 1 On/Off)
No. of compressors / circuits No. / No. 2 / 2
Control / capacity steps (%) % 25-100
Oil charge per circuit kg 2.9 2.9 4 4 4 4 3.7 7.2 7.2
Refrigerant charge (R290) per circuit kg 3.9 3.9 3.9 5 5 6.2 5.8 8.6 9.5
  • Notes and reference conditions (Enerblue PURPLEi HP technical catalogue):
  • (1) Outdoor air temperature 7 °C DB, 6 °C WB; water inlet-outlet temperature 40-45 °C.
  • (2) Total power input is the sum of compressors, fans and pump, in accordance with EN 14511.
  • (3) Outdoor air temperature 35 °C; water inlet-outlet temperature 12-7 °C.
  • (4) Sound power levels calculated in accordance with ISO 3744.
  • (5) Sound pressure levels at 1 m from the unit in free field.
  • (6) Sound levels at chiller operating conditions, water 12°/7 °C, outdoor air 35 °C.
  • (7) Values calculated in accordance with EN 14511.
  • (8) In accordance with European Regulation No 813/2013 and EN14511-EN14825 for an average climate (Strasbourg); application: medium temperature (55 °C), variable outlet.
  • (9) Not subject to EU Regulation No 811/2013, rated heat output > 70 kW.
  • (10) Performance in accordance with EN14511-EN14825 for an average climate (Strasbourg); application: fan coil (W7), variable outlet temperature.
  • (11) In accordance with European standard EN14511-EN14825 for an average climate (Strasbourg); application: low temperature (35 °C), variable outlet temperature.

Downloads

Catalogues and data sheets

Is the Enerblue PURPLEi HP range right for your project?

We'll help you choose the model and send you the technical documentation and a proposal.

Air-source heat pumps with natural refrigerant

Other ranges in this family

Enerblue PALLADIUM

Enerblue

Enerblue PALLADIUM

High-temperature reversible air-to-water heat pumps with R290 and an ultra-low sound level

Cooling capacity
40 – 135 kW
Heating capacity
50 – 164 kW
Energy
Electricity (air-source)
Efficiency
COP: 3.20 to 3.60
EER: 2.60 to 3.00
Enerblue PALLADIUM DWS

Enerblue

Enerblue PALLADIUM DWS

Heat pumps with priority high-temperature DHW production up to 70 ºC

Cooling capacity
40 – 135 kW
Heating capacity
50 – 164 kW
Energy
Electricity (air-source)
Efficiency
COP: 3.20 to 3.60
EER: 2.60 to 3.00
Enerblue PALLADIUM 4P

Enerblue

Enerblue PALLADIUM 4P

4-pipe multifunction heat pumps for simultaneous cooling and heating

Cooling capacity
42.4 – 143 kW
Heating capacity
50.2 – 164 kW
Energy
Electricity (air-source)
Efficiency
COP: 3.20 to 3.60
Enerblue PURPLE HP

Enerblue

Enerblue PURPLE HP

High-efficiency reversible air-to-water heat pumps with semi-hermetic reciprocating compressors

Cooling capacity
22 – 181 kW
Heating capacity
26 – 222 kW
Energy
Electricity (air-source)
Efficiency
SCOP: 3.33 to 4.60
SEER: 3.31 to 4.33
Enerblue LITHIUM

Enerblue

Enerblue LITHIUM

Large industrial-capacity reversible heat pumps with axial fans and R290

Cooling capacity
177 – 303 kW
Heating capacity
208 – 361 kW
Energy
Electricity (air-source)
Efficiency
SCOP: 3.15 to 3.40
SEER: 3.46 to 4.01