Skip to content

Enerblue · Air-source heat pumps with natural refrigerant

Enerblue PURPLE HP

High-efficiency reversible air-to-water heat pumps with semi-hermetic reciprocating compressors

Cooling capacity
22 – 181 kW
Heating capacity
26 – 222 kW
Efficiency
SCOP: 3.33 to 4.60
SEER: 3.31 to 4.33
Energy
Electricity (air-source)
Ask an engineer
Enerblue PURPLE HP

Technical data

Key data

Cooling capacity
22 – 181 kW
Heating capacity
26 – 222 kW
Rating conditions
Heating A7;W45 · Cooling A35;W7
Energy
Electricity (air-source)
Output temperature
Maximum water temperature: 62 ºC
Refrigerant
R290 (propane)
Efficiency
SCOP: 3.33 to 4.60
SEER: 3.31 to 4.33
Energy class
A+++

Main advantages

  • Extremely robust industrial semi-hermetic piston compressors
  • Top ErP A+++ energy rating at low temperature (with optional EC fans)
  • ATEX safety enclosure with extractor and leak detector as standard
  • Modular range with 1 or 2 refrigerant circuits (up to 4 capacity steps)

Models

Enerblue PURPLE HP models

Technical data from the manufacturer's data sheet.

PURPLE HP (1 compressor)

PURPLE HP (1 compressor)
Model Unit 8.110.112.115.120.122.125.130.132.135.140.150.1
HEATING (EN14511 VALUES) (A7;W45)
Nominal heat output (1), (7) kW 26.8 30.2 34.2 39.8 46.9 59.7 49.7 66.1 75 82.6 97.4 110.9
Total power input in heating (1), (2), (7) kW 8 9.1 9.7 11.1 12.8 13.7 16.4 18 21.9 23.8 28.1 32.6
COP (1), (7) 3.33 3.34 3.55 3.59 3.66 3.64 3.63 3.67 3.42 3.46 3.46 3.4
SEASONAL HEATING EFFICIENCY (AC FANS)
SCOP LT (water 35°C) (11) 3.33 3.38 3.44 3.49 3.54 3.53 3.53 3.64 3.35 3.38 3.39 3.43
Seasonal efficiency ηsh LT (11) % 130.3 132.3 134.6 136.6 138.5 138.1 138.4 142.5 131.1 132.3 132.5 134.1
LT efficiency class (11) A+
SCOP MT (water 55°C) (8) 2.85 2.85 2.88 2.9 2.95 2.94 2.93 3.02 2.84 2.84 2.84 2.84
Seasonal efficiency ηsh MT (8) % 111 111 112.2 113 115 114.6 114.2 117.8 110 110.5 110 110
MT efficiency class (8) A+
COOLING (EN14511 VALUES) (A35;W7) (AC FANS)
Nominal cooling capacity (3), (7) kW 22 25.9 29.3 33.1 38.7 31.6 49.9 55.5 58.2 66.2 76.4 88
Total power input in cooling (3), (2), (7) kW 7.4 8.8 9.8 11.2 12.5 16.4 12.1 18.8 20.9 23 29 34.3
EER (3), (7) 2.96 2.95 3 2.96 3.1 3.04 2.61 2.95 2.79 2.88 2.63 2.56
SEER (10) 3.31 3.47 3.54 3.47 3.71 3.64 3.68 3.71 3.64 3.75 3.58 3.49
Seasonal efficiency ηsc (10) % 129.4 135.8 138.6 135.8 145.4 142.6 144.2 145.4 142.6 147 140.2 136.6
SEASONAL HEATING EFFICIENCY (EC FANS)
SCOP LT (water 35°C) (11) 3.78 3.94 3.92 4.01 4.26 4.36 4.25 4.45 3.96 4.16 4.08 4.06
Seasonal efficiency ηsh LT (11) % 148 155 154 157 167 167 172 175 156 163 160 159
LT efficiency class (11) A+ A++ A++ A++ A++ A++ A++ A+++ A++ A++ A++ A++
SCOP MT (water 55°C) (8) 3.2 3.28 3.23 3.28 3.49 3.57 3.48 3.65 3.28 3.43 3.36 3.32
Seasonal efficiency ηsh MT (8) % 125 128 126 128 137 140 136 143 128 134 131 130
MT efficiency class (8) A++
COOLING (EN14511 VALUES) (A35;W7) (EC FANS)
SEER (10) 3.8 3.95 4.06 3.9 3.99 3.98 3.99 3.91 4.09 4.15 3.91 3.75
Seasonal efficiency ηsc (10) % 149 155 159 153 157 157 156 153 161 163 153 147
COMPRESSOR AND REFRIGERANT
Compressor type Reciprocating
No. of compressors / circuits No. / No. 1 / 1
Capacity steps No. 2
Oil charge per circuit kg 1.6 1.6 2.9 2.9 2.9 4 4 4 4 3.7 7.2 7.2
Refrigerant charge (R290) per circuit kg 2.4 2.6 2.8 2.8 3.6 3.8 4.7 5 6.1 6.1 8.5 8.5
  • Notes and reference conditions (Enerblue PURPLE HP technical catalogue):
  • (1) Outdoor air temperature 7 °C DB, 6 °C WB; water inlet-outlet temperature 40-45 °C.
  • (2) Total power input is the sum of compressors, fans and pump, in accordance with EN 14511.
  • (3) Outdoor air temperature 35 °C; water inlet-outlet temperature 12-7 °C.
  • (4) Sound power levels calculated in accordance with ISO 3744.
  • (5) Sound pressure levels at 1 m from the unit in free field.
  • (6) Sound levels at chiller operating conditions, water 12°/7 °C, outdoor air 35 °C.
  • (7) Values calculated in accordance with EN 14511.
  • (8) In accordance with European Regulation No 813/2013 and EN14511-EN14825 for an average climate (Strasbourg); application: medium temperature (55 °C), variable outlet.
  • (9) Not subject to EU Regulation No 811/2013, rated heat output > 70 kW.
  • (10) Performance in accordance with EN14511-EN14825 for an average climate (Strasbourg); application: fan coil (W7), variable outlet temperature.
  • (11) In accordance with European standard EN14511-EN14825 for an average climate (Strasbourg); application: low temperature (35 °C), variable outlet temperature.

PURPLE HP (2 compressors)

PURPLE HP (2 compressors)
Model Unit 15.220.222.225.230.232.235.240.250.2
HEATING (EN14511 VALUES) (A7;W45)
Nominal heat output (1), (7) kW 83.8 93.8 100.6 119.5 131.9 149.8 166.9 194.9 221.7
Total power input in heating (1), (2), (7) kW 23.1 25.7 27.3 32.8 36 43.1 47.5 56.5 65.7
COP (1), (7) 3.63 3.65 3.68 3.64 3.66 3.47 3.52 3.45 3.38
SEASONAL HEATING EFFICIENCY (AC FANS)
SCOP LT (water 35°C) (11) 3.64 3.8 3.87 3.82 3.84 3.55 3.6 3.51 3.54
Seasonal efficiency ηsh LT (11) % 142.6 149 151.8 150 150.8 138.8 140.9 137.5 138.5
LT efficiency class (11) A+ A+ A++ A+ A++ A+ A+ A+ A+
SCOP MT (water 55°C) (8) 3.08 3.2 3.22 3.2 3.21 3.01 3.07 2.99 2.98
Seasonal efficiency ηsh MT (8) % 120.2 125 125.8 125 125.4 120 117.4 116.6 116
MT efficiency class (8) A+ A++ A++ A++ (9) A++ (9) A+ (9) A+ (9) A+ (9) A+ (9)
COOLING (EN14511 VALUES) (A35;W7) (AC FANS)
Nominal cooling capacity (3), (7) kW 70.7 79.1 84.1 98.2 111.8 118.1 137 162.4 181.6
Total power input in cooling (3), (2), (7) kW 22.2 25.3 27.5 33.2 37.6 42 45.6 52 69.7
EER (3), (7) 3.18 3.13 3.05 2.96 2.97 2.82 3.01 2.32 2.6
SEER (10) 3.87 3.87 3.9 3.88 3.91 3.85 3.9 3.73 3.6
Seasonal efficiency ηsc (10) % 151.8 151.8 153 152.2 153.4 151 153 146.2 141
SEASONAL HEATING EFFICIENCY (EC FANS)
SCOP LT (water 35°C) (11) 4.21 4.36 4.44 4.52 4.6 4.15 4.25 4.19 4.14
Seasonal efficiency ηsh LT (11) % 165 171 175 178 181 163 167 165 163
LT efficiency class (11) A++ A++ A++ A+++ A+++ A++ A++ A++ A++
SCOP MT (water 55°C) (8) 3.5 3.62 3.64 3.73 3.8 3.45 3.57 3.51 3.45
Seasonal efficiency ηsh MT (8) % 137 142 143 146 149 135 140 138 135
MT efficiency class (8) A++
COOLING (EN14511 VALUES) (A35;W7) (EC FANS)
SEER (10) 4.29 4.24 4.22 4.23 4.15 4.33 4.32 4.09 3.87
Seasonal efficiency ηsc (10) % 169 167 166 166 163 170 170 161 152
COMPRESSOR AND REFRIGERANT
Compressor type Reciprocating
No. of compressors / circuits No. / No. 2 / 2
Capacity steps No. 4
Oil charge per circuit kg 2.9 2.9 4 4 4 4 3.7 7.2 7.2
Refrigerant charge (R290) per circuit kg 3.9 3.9 3.9 5 5 6.2 5.8 8.6 9.5
  • Notes and reference conditions (Enerblue PURPLE HP technical catalogue):
  • (1) Outdoor air temperature 7 °C DB, 6 °C WB; water inlet-outlet temperature 40-45 °C.
  • (2) Total power input is the sum of compressors, fans and pump, in accordance with EN 14511.
  • (3) Outdoor air temperature 35 °C; water inlet-outlet temperature 12-7 °C.
  • (4) Sound power levels calculated in accordance with ISO 3744.
  • (5) Sound pressure levels at 1 m from the unit in free field.
  • (6) Sound levels at chiller operating conditions, water 12°/7 °C, outdoor air 35 °C.
  • (7) Values calculated in accordance with EN 14511.
  • (8) In accordance with European Regulation No 813/2013 and EN14511-EN14825 for an average climate (Strasbourg); application: medium temperature (55 °C), variable outlet.
  • (9) Not subject to EU Regulation No 811/2013, rated heat output > 70 kW.
  • (10) Performance in accordance with EN14511-EN14825 for an average climate (Strasbourg); application: fan coil (W7), variable outlet temperature.
  • (11) In accordance with European standard EN14511-EN14825 for an average climate (Strasbourg); application: low temperature (35 °C), variable outlet temperature.

Downloads

Catalogues and data sheets

Is the Enerblue PURPLE HP range right for your project?

We'll help you choose the model and send you the technical documentation and a proposal.

Air-source heat pumps with natural refrigerant

Other ranges in this family

Enerblue PALLADIUM

Enerblue

Enerblue PALLADIUM

High-temperature reversible air-to-water heat pumps with R290 and an ultra-low sound level

Cooling capacity
40 – 135 kW
Heating capacity
50 – 164 kW
Energy
Electricity (air-source)
Efficiency
COP: 3.20 to 3.60
EER: 2.60 to 3.00
Enerblue PALLADIUM DWS

Enerblue

Enerblue PALLADIUM DWS

Heat pumps with priority high-temperature DHW production up to 70 ºC

Cooling capacity
40 – 135 kW
Heating capacity
50 – 164 kW
Energy
Electricity (air-source)
Efficiency
COP: 3.20 to 3.60
EER: 2.60 to 3.00
Enerblue PALLADIUM 4P

Enerblue

Enerblue PALLADIUM 4P

4-pipe multifunction heat pumps for simultaneous cooling and heating

Cooling capacity
42.4 – 143 kW
Heating capacity
50.2 – 164 kW
Energy
Electricity (air-source)
Efficiency
COP: 3.20 to 3.60
Enerblue PURPLEi HP

Enerblue

Enerblue PURPLEi HP

Modulating reversible air-to-water heat pumps with inverter technology and R290

Cooling capacity
22 – 181 kW
Heating capacity
26 – 221 kW
Energy
Electricity (air-source)
Efficiency
SCOP: 3.33 to 4.38
SEER: 3.12 to 4.21
Enerblue LITHIUM

Enerblue

Enerblue LITHIUM

Large industrial-capacity reversible heat pumps with axial fans and R290

Cooling capacity
177 – 303 kW
Heating capacity
208 – 361 kW
Energy
Electricity (air-source)
Efficiency
SCOP: 3.15 to 3.40
SEER: 3.46 to 4.01

Be the first to know

Sign up for the latest news, exclusives and offers from Absorsistem

To download the document, please enter your email address.

Thank you! Your download has started.

Something went wrong. Please try again later.

Please check the highlighted fields.