Skip to content

Enerblue · Air-source heat pumps with natural refrigerant

Enerblue LITHIUM

Large industrial-capacity reversible heat pumps with axial fans and R290

Cooling capacity
177 – 303 kW
Heating capacity
208 – 361 kW
Efficiency
SCOP: 3.15 to 3.40
SEER: 3.46 to 4.01
Energy
Electricity (air-source)
Ask an engineer
Enerblue LITHIUM

Technical data

Key data

Cooling capacity
177 – 303 kW
Heating capacity
208 – 361 kW
Rating conditions
Heating A7;W45 · Cooling A35;W7
Energy
Electricity (air-source)
Output temperature
Maximum water temperature: 60 ºC
Refrigerant
R290 (propane)
Efficiency
SCOP: 3.15 to 3.40
SEER: 3.46 to 4.01
Energy class
A++

Main advantages

  • Leading industrial unit capacity with R290 (up to 361 kW of heating in a single unit)
  • Three compression configurations: standard on/off, mixed inverter or Full Inverter
  • Very low starting current in the Full Inverter version

Models

Enerblue LITHIUM models

Technical data from the manufacturer's data sheet.

LITHIUM (On-Off)

LITHIUM (On-Off)
Model Unit 220.2260.2290.2320.2370.2
HEATING (EN 14511 VALUES) (A7; W45)
Nominal heat output (1), (7) kW 213 235 286 306 361
Total power input in heating (1), (7) kW 63.9 67.8 80.8 87.2 103
COP (1), (7) 3.33 3.47 3.54 3.51 3.5
HEATING (EN 14511 VALUES) (A7; W55)
Nominal heat output (2), (7) kW 206 226 273 293 345
Total power input in heating (2), (7) kW 70 73.3 87.6 94.3 112
COP (2), (7) 2.94 3.08 3.12 3.11 3.08
SEASONAL ENERGY INDICES (ErP / Ecodesign)
SEER (water 7°C) (10) 3.66 3.71 4.01 3.96 3.86
Seasonal efficiency ηsc (10) % 143.3 145.3 157.3 155.2 151.3
SCOP MT (water 55°C) (8) 3.27 3.34 3.39 3.39 3.4
Seasonal efficiency ηsh MT (8) % 127.6 130.7 132.5 132.5 132.9
MT seasonal efficiency class (8), (9) A++ (*)
COOLING (EN 14511 VALUES) (A35; W7)
Nominal cooling capacity (3), (7) kW 183 203 240 260 303
Total power input in cooling (3), (7) kW 71.7 77.4 84.5 92.9 109
EER (3), (7) 2.55 2.62 2.84 2.8 2.78
USER-SIDE HEAT EXCHANGER (PLATE)
Heating water flow (A7/W45) (1) m³/h 37 40.8 49.6 53.1 62.5
Heating pressure drop (A7/W45) (1) kPa 17.4 18.8 22.7 22 28.3
Heating water flow (A7/W55) (2) m³/h 22.4 24.6 29.7 31.8 37.5
Heating pressure drop (A7/W55) (2) kPa 7.5 8 9.6 9.3 12
Cooling water flow (A35/W7) (3) m³/h 31.5 35 41.3 44.7 52.1
Cooling pressure drop (A35/W7) (3) kPa 16.3 15.2 17.9 20.8 26.3
COMPRESSOR AND REFRIGERANT (R290)
Compressor type Reciprocating
No. of compressors / circuits No. / No. 2 / 2
Capacity steps No. 4
Oil charge per circuit kg 3.5 8.5 8.5 8.5 8.5
Refrigerant charge (R290) per circuit kg 10 10.2 14 14.2 17
FANS, ACOUSTICS, DIMENSIONS AND ELECTRICAL DATA
No. of axial fans No. 4 4 8 8 8
Total air flow (1) m³/h 82,404 82,427 171,008 171,072 164,785
Hydraulic connections (Victaulic type) inches 3" 3" 4" 4" 4"
Sound power level Lw (STD) (4), (6) dB(A) 91 91 93 93 93
Sound pressure level Lp @10m (5), (6) dB(A) 71 71 72 72 72
Dimensions (L x W x H) mm 3230x2384x2619 3230x2384x2619 5843x2384x2619 5843x2384x2619 5843x2384x2619
Maximum current draw (without/with pump) (1), (3) A 150 (156) 168 (174) 199 (207) 213 (221) 243 (251)
Maximum starting current (without/with pump) (2), (3) A 331 (338) 408 (415) 492 (500) 527 (535) 542 (550)
  • Notes and reference conditions (Enerblue LITHIUM / LITHIUMi / FULL INVERTER technical catalogue):
  • (1) Outdoor air temperature 7 °C DB, 6 °C WB; condenser water inlet-outlet temperature 40-45 °C.
  • (2) Outdoor air temperature 7 °C DB, 6 °C WB; condenser water inlet-outlet temperature 47-55 °C.
  • (3) Outdoor air temperature 35 °C; evaporator water inlet-outlet temperature 12-7 °C.
  • (4) Sound power levels calculated in accordance with ISO 3744.
  • (5) Sound pressure levels at 10 metres from the unit in free field.
  • (6) Sound levels at chiller operating conditions, water 12°/7 °C, outdoor air 35 °C.
  • (7) Values in accordance with EN 14511-3:2022.
  • (8) In accordance with European Directive No 813/2013 and EN 14511-EN 14825 for an average climate (Strasbourg); application: medium temperature (55 °C), variable outlet temperature.
  • (9) Units marked with (*) are not subject to EU Regulation No 811/2013 (rated heat output > 70 kW).
  • (10) In accordance with European Directive No 813/2013 and EN 14511-EN 14825 for an average climate (Strasbourg); application: fan coil (7 °C), variable outlet temperature.

LITHIUMi (Inverter)

LITHIUMi (Inverter)
Model Unit 220.2260.2290.2320.2370.2
HEATING (EN 14511 VALUES) (A7; W45)
Nominal heat output (1), (7) kW 211 234 283 305 360
Total power input in heating (1), (7) kW 63.3 67.6 80.9 87.7 104
COP (1), (7) 3.33 3.46 3.5 3.48 3.46
HEATING (EN 14511 VALUES) (A7; W55)
Nominal heat output (2), (7) kW 204 226 272 292 345
Total power input in heating (2), (7) kW 69.7 73.8 88.4 95.4 113
COP (2), (7) 2.93 3.06 3.08 3.06 3.05
SEASONAL ENERGY INDICES (ErP / Ecodesign)
SEER (water 7°C) (10) 3.5 3.46 3.8 3.74 3.63
Seasonal efficiency ηsc (10) % 136.8 135.2 148.9 146.5 142.1
SCOP MT (water 55°C) (8) 3.15 3.15 3.23 3.19 3.16
Seasonal efficiency ηsh MT (8) % 122.9 122.9 126.3 124.5 123.2
MT seasonal efficiency class (8), (9) A+ (*) A+ (*) A++ (*) A+ (*) A+ (*)
COOLING (EN 14511 VALUES) (A35; W7)
Nominal cooling capacity (3), (7) kW 180 202 236 257 301
Total power input in cooling (3), (7) kW 70.7 77.3 84.1 93.3 110
EER (3), (7) 2.55 2.61 2.81 2.75 2.74
USER-SIDE HEAT EXCHANGER (PLATE)
Heating water flow (A7/W45) (1) m³/h 36.6 40.5 49.1 52.8 62.5
Heating pressure drop (A7/W45) (1) kPa 17.1 18.6 22.4 21.8 28.3
Heating water flow (A7/W55) (2) m³/h 22.2 24.6 29.5 31.8 37.5
Heating pressure drop (A7/W55) (2) kPa 7.4 8 9.6 9.3 12
Cooling water flow (A35/W7) (3) m³/h 31 34.7 40.6 44.2 51.8
Cooling pressure drop (A35/W7) (3) kPa 15.8 15 17.5 20.4 26.1
COMPRESSOR AND REFRIGERANT (INVERTER TECHNOLOGY)
Compressor type Reciprocating (1 Inv + 1 On/Off)
No. of compressors / circuits No. / No. 2 / 2
Capacity steps / control % 25-100%
Oil charge per circuit kg 3.5 8.5 8.5 8.5 8.5
Refrigerant charge (R290) per circuit kg 10 10.2 14 14.2 17
FANS, ACOUSTICS, DIMENSIONS AND ELECTRICAL DATA
No. of axial fans No. 4 4 8 8 8
Total air flow (1) m³/h 82,391 82,432 170,959 170,961 164,712
Hydraulic connections (Victaulic type) inches 3" 3" 4" 4" 4"
Sound power level Lw (STD) (4), (6) dB(A) 91 91 93 93 93
Sound pressure level Lp @10m (5), (6) dB(A) 71 71 72 72 72
Dimensions (L x W x H) mm 3230x2384x2619 3230x2384x2619 5843x2384x2619 5843x2384x2619 5843x2384x2619
Maximum current draw (without/with pump) (1), (3) A 153 (160) 162 (169) 195 (203) 211 (219) 238 (246)
Maximum starting current (without/with pump) (2), (3) A 335 (341) 403 (409) 488 (496) 525 (533) 537 (545)
  • Notes and reference conditions (Enerblue LITHIUM / LITHIUMi / FULL INVERTER technical catalogue):
  • (1) Outdoor air temperature 7 °C DB, 6 °C WB; condenser water inlet-outlet temperature 40-45 °C.
  • (2) Outdoor air temperature 7 °C DB, 6 °C WB; condenser water inlet-outlet temperature 47-55 °C.
  • (3) Outdoor air temperature 35 °C; evaporator water inlet-outlet temperature 12-7 °C.
  • (4) Sound power levels calculated in accordance with ISO 3744.
  • (5) Sound pressure levels at 10 metres from the unit in free field.
  • (6) Sound levels at chiller operating conditions, water 12°/7 °C, outdoor air 35 °C.
  • (7) Values in accordance with EN 14511-3:2022.
  • (8) In accordance with European Directive No 813/2013 and EN 14511-EN 14825 for an average climate (Strasbourg); application: medium temperature (55 °C), variable outlet temperature.
  • (9) Units marked with (*) are not subject to EU Regulation No 811/2013 (rated heat output > 70 kW).
  • (10) In accordance with European Directive No 813/2013 and EN 14511-EN 14825 for an average climate (Strasbourg); application: fan coil (7 °C), variable outlet temperature.

LITHIUMi (Full Inverter)

LITHIUMi (Full Inverter)
Model Unit 220.2260.2290.2320.2370.2
HEATING (EN 14511 VALUES) (A7; W45)
Nominal heat output (1), (7) kW 208 232 280 303 360
Total power input in heating (1), (7) kW 62.7 67.3 80.9 88.2 105
COP (1), (7) 3.32 3.45 3.46 3.44 3.43
HEATING (EN 14511 VALUES) (A7; W55)
Nominal heat output (2), (7) kW 202 225 270 292 345
Total power input in heating (2), (7) kW 69.3 74.4 89.2 96.6 114
COP (2), (7) 2.91 3.02 3.03 3.02 3.03
SEASONAL ENERGY INDICES (ErP / Ecodesign)
SEER (water 7°C) (10) 3.56 3.57 3.91 3.83 3.73
Seasonal efficiency ηsc (10) % 139.3 139.7 153.2 150.1 146.1
SCOP MT (water 55°C) (8) 3.23 3.27 3.28 3.28 3.29
Seasonal efficiency ηsh MT (8) % 126.1 127.9 128 128 128.4
MT seasonal efficiency class (8), (9) A++ (*)
COOLING (EN 14511 VALUES) (A35; W7)
Nominal cooling capacity (3), (7) kW 177 200 232 254 299
Total power input in cooling (3), (7) kW 69.8 77.4 83.7 93.7 111
EER (3), (7) 2.54 2.58 2.77 2.71 2.69
USER-SIDE HEAT EXCHANGER (PLATE)
Heating water flow (A7/W45) (1) m³/h 36.1 40.2 48.5 52.6 62.4
Heating pressure drop (A7/W45) (1) kPa 16.7 18.4 22 21.7 28.2
Heating water flow (A7/W55) (2) m³/h 22 24.5 29.4 31.7 37.5
Heating pressure drop (A7/W55) (2) kPa 7.3 8 9.5 9.3 12
Cooling water flow (A35/W7) (3) m³/h 30.4 34.3 39.9 43.7 51.4
Cooling pressure drop (A35/W7) (3) kPa 15.4 14.8 17 20.1 25.8
COMPRESSOR AND REFRIGERANT (FULL INVERTER)
Compressor type Reciprocating Full Inverter
No. of compressors / circuits No. / No. 2 / 2
Capacity steps / control % 25-100%
Oil charge per circuit kg 3.5 3.5 3.5 3.5 8.5
Refrigerant charge (R290) per circuit kg 10 10.2 14 14.2 17
FANS, ACOUSTICS, DIMENSIONS AND ELECTRICAL DATA
No. of axial fans No. 4 4 8 8 8
Total air flow (1) m³/h 82,376 82,443 170,945 171,107 164,843
Hydraulic connections (Victaulic type) inches 3" 3" 4" 4" 4"
Sound power level Lw (STD) (4), (6) dB(A) 91 91 93 93 93
Sound pressure level Lp @10m (5), (6) dB(A) 71 71 72 72 72
Dimensions (L x W x H) mm 3230x2384x2619 3230x2384x2619 5843x2384x2619 5843x2384x2619 5843x2384x2619
Maximum current draw (without/with pump) (1), (3) A 157 (163) 157 (163) 191 (199) 209 (217) 233 (241)
Maximum starting current (without/with pump) (2), (3) A 157 (163) 157 (163) 191 (199) 209 (217) 233 (241)
  • Notes and reference conditions (Enerblue LITHIUM / LITHIUMi / FULL INVERTER technical catalogue):
  • (1) Outdoor air temperature 7 °C DB, 6 °C WB; condenser water inlet-outlet temperature 40-45 °C.
  • (2) Outdoor air temperature 7 °C DB, 6 °C WB; condenser water inlet-outlet temperature 47-55 °C.
  • (3) Outdoor air temperature 35 °C; evaporator water inlet-outlet temperature 12-7 °C.
  • (4) Sound power levels calculated in accordance with ISO 3744.
  • (5) Sound pressure levels at 10 metres from the unit in free field.
  • (6) Sound levels at chiller operating conditions, water 12°/7 °C, outdoor air 35 °C.
  • (7) Values in accordance with EN 14511-3:2022.
  • (8) In accordance with European Directive No 813/2013 and EN 14511-EN 14825 for an average climate (Strasbourg); application: medium temperature (55 °C), variable outlet temperature.
  • (9) Units marked with (*) are not subject to EU Regulation No 811/2013 (rated heat output > 70 kW).
  • (10) In accordance with European Directive No 813/2013 and EN 14511-EN 14825 for an average climate (Strasbourg); application: fan coil (7 °C), variable outlet temperature.

Downloads

Catalogues and data sheets

Is the Enerblue LITHIUM range right for your project?

We'll help you choose the model and send you the technical documentation and a proposal.

Air-source heat pumps with natural refrigerant

Other ranges in this family

Enerblue PALLADIUM

Enerblue

Enerblue PALLADIUM

High-temperature reversible air-to-water heat pumps with R290 and an ultra-low sound level

Cooling capacity
40 – 135 kW
Heating capacity
50 – 164 kW
Energy
Electricity (air-source)
Efficiency
COP: 3.20 to 3.60
EER: 2.60 to 3.00
Enerblue PALLADIUM DWS

Enerblue

Enerblue PALLADIUM DWS

Heat pumps with priority high-temperature DHW production up to 70 ºC

Cooling capacity
40 – 135 kW
Heating capacity
50 – 164 kW
Energy
Electricity (air-source)
Efficiency
COP: 3.20 to 3.60
EER: 2.60 to 3.00
Enerblue PALLADIUM 4P

Enerblue

Enerblue PALLADIUM 4P

4-pipe multifunction heat pumps for simultaneous cooling and heating

Cooling capacity
42.4 – 143 kW
Heating capacity
50.2 – 164 kW
Energy
Electricity (air-source)
Efficiency
COP: 3.20 to 3.60
Enerblue PURPLE HP

Enerblue

Enerblue PURPLE HP

High-efficiency reversible air-to-water heat pumps with semi-hermetic reciprocating compressors

Cooling capacity
22 – 181 kW
Heating capacity
26 – 222 kW
Energy
Electricity (air-source)
Efficiency
SCOP: 3.33 to 4.60
SEER: 3.31 to 4.33
Enerblue PURPLEi HP

Enerblue

Enerblue PURPLEi HP

Modulating reversible air-to-water heat pumps with inverter technology and R290

Cooling capacity
22 – 181 kW
Heating capacity
26 – 221 kW
Energy
Electricity (air-source)
Efficiency
SCOP: 3.33 to 4.38
SEER: 3.12 to 4.21

Be the first to know

Sign up for the latest news, exclusives and offers from Absorsistem

To download the document, please enter your email address.

Thank you! Your download has started.

Something went wrong. Please try again later.

Please check the highlighted fields.