Robur
Robur GAHP A Plus
Air-source gas absorption heat pumps for heating and DHW
- Heating capacity
- 44.6 kW
- Energy
- Natural gas or LPG + air
- Efficiency
- GUE 172 %
- Energy class
- A+ (A++ low-noise version)
Aisin · Gas heat pumps
Gas engine-driven compression heat pumps with a Toyota engine, for VRF or hydronic (AWS) systems
Technical data
Models
Technical data from the manufacturer's data sheet.
| Model | Unit | AWGP450F1 (16 HP) | AWGP560F1 (20 HP) | AWGP710F1 (25 HP) | AWGP850F1 (30 HP) | 450+450 (16+16 HP) | 450+560 (16+20 HP) | 560+560 (20+20 HP) | 560+710 (20+25 HP) | 710+710 (25+25 HP) | 710+850 (25+30 HP) | 850+850 (30+30 HP) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| COOLING PERFORMANCE | ||||||||||||
| Nominal cooling capacity | kW | 45 | 56 | 71 | 85 | 90 | 101 | 112 | 127 | 142 | 156 | 170 |
| Nominal consumption, cooling mode | kW | 31.4 | 38.9 | 54.4 | 71.2 | 62.8 | 70.3 | 77.8 | 93.3 | 108.8 | 125.6 | 142.2 |
| G.U.E. cooling mode | 1.43 | 1.44 | 1.31 | 1.19 | 1.43 | 1.44 | 1.44 | 1.36 | 1.31 | 1.24 | 1.19 | |
| SPER cooling mode (seasonal efficiency) | 2.39 | 2.44 | 2.42 | 2.17 | 2.39 | 2.44 | 2.44 | 2.43 | 2.42 | 2.3 | 2.17 | |
| HEATING AND HEAT RECOVERY PERFORMANCE | ||||||||||||
| Nominal heating capacity | kW | 50 | 63 | 80 | 95 | 100 | 113 | 126 | 143 | 160 | 175 | 190 |
| Nominal consumption, heating mode | kW | 29.8 | 38.1 | 53.9 | 68 | 106 | 120 | 134 | 151 | 168 | 179 | 190 |
| Maximum heating output (29°C) | kW | 53 | 67 | 84 | 95 | 59.6 | 67.9 | 76.2 | 92 | 107.8 | 121.9 | 136 |
| Maximum heating consumption (29°C) | kW | 40.1 | 79.6 | 56.9 | 86.8 | 80.2 | 97 | 113.8 | 136.5 | 159.2 | 166.4 | 173.6 |
| G.U.E. heating mode | 1.68 | 1.65 | 1.48 | 1.4 | 1.68 | 1.66 | 1.65 | 1.55 | 1.48 | 1.44 | 1.39 | |
| SPER heating mode (class A++) | 1.48 | 1.55 | 1.54 | 1.52 | 1.48 | 1.52 | 1.55 | 1.54 | 1.54 | 1.53 | 1.52 | |
| Maximum heat recovery (free DHW) | kW | 15.7 | 27.2 | 19.5 | 35.6 | 31.4 | 35.6 | 39 | 46.7 | 54.4 | 62.8 | 71.2 |
| ELECTRICAL DATA AND COMPONENTS | ||||||||||||
| Power supply | V / Hz | Single-phase 220V - 50 Hz | ||||||||||
| Rated current | A | 20 | 20 | 20 | 20 | 40 | 40 | 40 | 40 | 40 | 40 | 40 |
| Electrical power input (min/max) | kW | 0.50/0.64 | 0.74/1.19 | 0.62/0.91 | 1.12/1.49 | 1.00/1.28 | 1.24/1.83 | 1.48/2.38 | 1.36/2.10 | 1.24/1.82 | 1.74/2.40 | 2.24/2.98 |
| Compressor type | Variable-capacity scroll x 2 | Variable-capacity scroll x 2 | Variable-capacity scroll x 2 | Variable-capacity scroll x 3 | 2x (Scroll x 2) | 2x (Scroll x 2) | 2x (Scroll x 2) | 2x (Scroll x 2) | 2x (Scroll x 2) | Scroll x2 + Scroll x3 | 2x (Scroll x 3) | |
| Refrigerant / charge per unit | R410A - 11.5 kg | R410A - 11.5 kg | R410A - 11.5 kg | R410A - 11.5 kg | R410A - 2x 11.5 kg | R410A - 2x 11.5 kg | R410A - 2x 11.5 kg | R410A - 2x 11.5 kg | R410A - 2x 11.5 kg | R410A - 2x 11.5 kg | R410A - 2x 11.5 kg | |
| ACOUSTICS, DIMENSIONS AND WEIGHTS | ||||||||||||
| Sound pressure | dB(A) | 58 | 59 | 62 | 65 | 61 | 62 | 62 | 64 | 65 | 67 | 68 |
| Sound power | dB | 75 | 76 | 82 | 86 | 78 | 79 | 79 | 84 | 85 | 88 | 89 |
| Outside dimensions (H x L x D) | mm | 2245 x 1660 x 880 | 2245 x 1660 x 880 | 2245 x 1660 x 880 | 2245 x 1660 x 880 | 2x (2245 x 1660 x 880) | 2x (2245 x 1660 x 880) | 2x (2245 x 1660 x 880) | 2x (2245 x 1660 x 880) | 2x (2245 x 1660 x 880) | 2x (2245 x 1660 x 880) | 2x (2245 x 1660 x 880) |
| Total unit weight | kg | 765 | 795 | 870 | 870 | 1,530 | 1,560 | 1,590 | 1,665 | 1,740 | 1,740 | 1,740 |
| Maximum number of connectable indoor units | units | 26 | 41 | 33 | 50 | 63 | 63 | 63 | 63 | 63 | 63 | 63 |
| Preventive maintenance interval | h | 10,000 | ||||||||||
| Engine oil change interval | h | 30,000 | ||||||||||
| Model | Unit | AWS 16HP-F1(J) | AWS 20HP-F1(J) | AWS 25HP-F1(J) | AWS 30HP-F1(J) | AWS 40HP TWIN (16+16) | AWS TWIN (16+20) | AWS 50HP TWIN (16+25) | AWS TWIN (20+20) | AWS TWIN (20+25) | AWS 50HP TWIN (25+25) | AWS 60HP TWIN (30+30) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| COOLING PERFORMANCE (CHILLED WATER) | ||||||||||||
| Nominal cooling capacity | kW | 42.5 | 53 | 63.5 | 74.5 | 85 | 95.5 | 106 | 106 | 116.5 | 127 | 149 |
| Nominal consumption, cooling mode | kW | 30 | 43 | 56 | 70.7 | 60 | 73 | 99 | 86 | 86 | 112 | 141.4 |
| G.U.E. cooling mode | 1.13 | 1.23 | 1.42 | 1.05 | 1.42 | 1.31 | 1.17 | 1.24 | 1.23 | 1.13 | 1.05 | |
| SPER cooling mode (seasonal efficiency) | 1.89 | 1.89 | 1.87 | 1.91 | 1.89 | 1.89 | 1.89 | 1.88 | 1.88 | 1.87 | 1.91 | |
| Minimum water outlet temperature | °C | 7 | ||||||||||
| HEATING AND HEAT RECOVERY PERFORMANCE (HOT WATER) | ||||||||||||
| Nominal heating capacity | kW | 50 | 62.5 | 77 | 87.5 | 100 | 112.5 | 127 | 125 | 139.5 | 154 | 175 |
| Nominal consumption, heating mode | kW | 34 | 42.5 | 54.2 | 61.5 | 68 | 76.5 | 96.7 | 88.2 | 85 | 108.4 | 123 |
| Maximum heating output | kW | 68 | 77 | 53.5 | 91 | 107 | 121.5 | 136 | 130.5 | 145 | 154 | 182 |
| Maximum heating consumption | kW | 37.3 | 53.2 | 58.5 | 75.7 | 74.6 | 90.5 | 106.4 | 111.7 | 95.8 | 117 | 151.4 |
| G.U.E. heating mode | 1.47 | 1.47 | 1.42 | 1.42 | 1.47 | 1.47 | 1.47 | 1.44 | 1.44 | 1.42 | 1.42 | |
| SPER heating mode (class A++) | 1.57 | 1.55 | 1.54 | 1.51 | 1.57 | 1.56 | 1.55 | 1.55 | 1.54 | 1.54 | 1.53 | |
| Maximum heat recovery (free DHW) | kW | 19.5 | 23.5 | 30.5 | 44.5 | 39 | 43 | 50 | 54 | 47 | 61 | 89 |
| Maximum water outlet temperature | °C | 50 | ||||||||||
| HYDRAULIC CIRCUIT AND MODULATION | ||||||||||||
| Nominal water flow | m³/h | 10 | 12 | 8 | 14 | 20 | 22 | 24 | 24 | 26 | 28 | 32 |
| Output modulation | % | 35-100 | 28-100 | 23-100 | 22-100 | 20-100 | 20-100 | 20-100 | 20-100 | 20-100 | 20-100 | 20-100 |
| Hydraulic pipe diameter | DN 40 | DN 40 | DN 40 | DN 40 | 2 1/2" | 2 1/2" | 2 1/2" | 2 1/2" | 2 1/2" | 2 1/2" | 2 1/2" | |
| Internal heat exchanger pressure drop | mca | 3.3 | 4.6 | 2.2 | 4.8 | 3.3 | 4.6 | 4.8 | 4.6 | 4.6 | 4.8 | 4.8 |
| ELECTRICAL DATA AND MODULE | ||||||||||||
| Module power supply | V / Ph / Hz | 220V / Single-phase / 50 Hz | ||||||||||
| Electrical power input (with pump) | W | 550 | 770 | 700 | 900 | 1,100 | 1,320 | 1,400 | 1,400 | 1,470 | 1,600 | 1,800 |
| Electrical power input (without pump) | W | 190 | 190 | 190 | 190 | 200 | 200 | 200 | 200 | 200 | 200 | 200 |
| Rated current (without pump) | A | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| AWS MODULE DIMENSIONS AND WEIGHTS | ||||||||||||
| AWS module dimensions (H x L x D) | mm | 915 x 710 x 1020 | ||||||||||
| AWS module weight (with pump / without pump) | kg | 204/177 | 204/177 | 207/180 | 207/180 | 236 | 236 | 236 | 236 | 236 | 236 | 236 |
| Connectable gas heat pump units | units | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Downloads
We'll help you choose the model and send you the technical documentation and a proposal.
Gas heat pumps
Robur
Air-source gas absorption heat pumps for heating and DHW
Robur
Reversible gas absorption heat pumps: heating, cooling and DHW
Robur
Ground-source gas absorption heat pumps
Robur
Water-source gas absorption heat pumps
Robur
Prefabricated thermal plants combining heat pumps, chillers and boilers