Skip to content

IVAR · Boilers and steam generators

IVAR TRINOX

Large industrial boilers with 3 true flue gas passes and low NOx

Heating capacity
1,165 – 10,560 kW
Efficiency
94 %
Energy
Natural gas, LPG, diesel oil
Ask an engineer
IVAR TRINOX

Technical data

Key data

Heating capacity
1,165 – 10,560 kW
Energy
Natural gas, LPG, diesel oil
Output temperature
Up to 110 ºC
Efficiency
94 %

Main advantages

  • Three true flue gas passes and high thermal inertia
  • Low NOx emissions
  • High water volume to avoid frequent starts

Models

IVAR TRINOX models

Technical data from the manufacturer's data sheet.

TRINOX (1000-9000)
Model Unit 10001200150017502150258030003500400043005000600075009000
PERFORMANCE AND HEAT OUTPUTS
Rated output [kW] kW 1,165 1,410 1,760 2,040 2,510 3,020 3,520 4,090 4,680 5,030 5,830 7,020 8,760 10,560
Rated output [kcal/h x1000] kcal/h x1000 1,002 1,213 1,514 1,754 2,159 2,597 3,027 3,517 4,025 4,326 5,014 6,037 7,534 9,082
Furnace output [kW] kW 1,260 1,522 1,902 2,210 2,710 3,260 3,810 4,420 5,050 5,450 6,310 7,590 9,460 11,400
Furnace output [kcal/h x1000] kcal/h x1000 1,084 1,309 1,636 1,901 2,331 2,804 3,277 3,801 4,343 4,687 5,427 6,527 8,136 9,804
HYDRAULIC AND COMBUSTION PARAMETERS
Combustion chamber pressure mbar 4.5 6.6 5.3 5.6 5.6 5.5 7.7 5.4 7 8.2 5.6 8.4 8.1 8.7
Water-side pressure drop (Δt 15°C) mbar 75 105 72 90 55 72 95 130 170 180 120 150 220 180
Water capacity dm³ (L) 2,247 2,476 3,388 3,649 5,020 5,610 6,332 7,793 8,561 8,561 11,984 13,227 16,952 19,733
Max. operating pressures bar 5 / 6 / 8
Maximum temperature °C 110
PHYSICAL DIMENSIONS
Overall outside width (B) mm 1,580 1,580 1,800 1,800 1,930 2,050 2,050 2,260 2,260 2,260 2,500 2,500 2,750 2,910
Overall height (H) mm 1,930 1,930 2,200 2,200 2,330 2,450 2,460 2,660 2,660 2,660 2,950 2,950 3,200 3,360
Overall outside length (L) mm 3,240 3,490 3,650 3,900 4,510 4,510 4,960 5,100 5,550 5,550 6,070 6,570 7,020 7,320
Base frame width (B1) mm 1,100 1,100 1,250 1,250 1,250 1,310 1,310 1,500 1,500 1,500 1,620 1,620 1,800 1,900
Height to furnace axis (H1) mm 790 790 915 915 960 995 995 1,070 1,070 1,070 1,225 1,225 1,305 1,355
Height to flue axis (H2) mm 1,250 1,250 1,450 1,450 1,530 1,650 1,650 1,780 1,780 1,780 1,955 1,955 2,110 2,210
Distance between support bases (L1) mm 1,750 2,000 1,850 2,000 2,400 2,400 2,720 2,750 3,000 3,000 3,200 3,500 3,700 4,000
Front to flow connection distance (L2) mm 640 640 720 720 830 830 830 860 860 860 922 922 1,022 1,022
Distance between flow and return connections (L3) mm 1,300 1,550 1,400 1,650 1,970 1,970 2,420 2,450 2,800 2,800 3,000 3,450 3,600 3,900
Distance between return and expansion vessel (L4) mm 650 650 700 700 750 750 750 750 800 800 900 900 1,000 1,000
Distance between expansion vessels (L5) mm 200 200 220 220 220 220 250 250 300 300 300 350 350 350
CONNECTIONS AND WEIGHT
Flow / return connections (f / r) DN DN 125 DN 125 DN 150 DN 150 DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 DN 250 DN 250 DN 250 DN 300
Expansion vessel connection (2x v) DN / inch 1"1/2 1"1/2 2" 2" 2" 2" DN 65 DN 65 DN 80 DN 80 DN 80 DN 100 DN 100 DN 100
Drain connection (Scarico S) DN DN 40
Flue outlet diameter (camino Ø) mm 400 400 450 450 500 500 500 600 600 600 700 700 800 900
Empty weight (5 bar version) kg 3,320 3,550 4,700 4,950 5,700 7,110 7,650 9,250 10,050 10,200 13,300 14,200 17,800 22,000
Empty weight (6 bar version) kg 3,480 3,820 4,850 5,000 5,950 7,530 8,150 9,700 10,050 10,200 13,800 14,660 18,250 22,600
Empty weight (8 bar version) kg 3,720 3,990 5,220 5,500 6,450 8,120 8,750 10,400 11,350 11,500 14,950 15,950 18,950 23,500

Downloads

Catalogues and data sheets

Is the IVAR TRINOX range right for your project?

We'll help you choose the model and send you the technical documentation and a proposal.

Boilers and steam generators

Other ranges in this family

IVAR SupeRAC

IVAR

IVAR SupeRAC

6 bar monobloc hot water boilers with flame reversal chamber and high efficiency

Heating capacity
94 – 4,150 kW
Energy
Natural gas, LPG, diesel oil, biogas
Efficiency
91 - 93%
IVAR SupeRAC 2F

IVAR

IVAR SupeRAC 2F

6 bar hot water boilers with twin stacked furnaces for wide modulation and redundancy

Heating capacity
186 – 814 kW
Energy
Natural gas, LPG, diesel oil, biogas
Efficiency
91 - 93%
IVAR SupeRAC AR

IVAR

IVAR SupeRAC AR

High-efficiency hot water boilers with 3 flue gas passes and low NOx

Heating capacity
81 – 3,610 kW
Energy
Natural gas, LPG, diesel oil, biogas
Efficiency
96.8 to 98.0%
IVAR ECOCOND

IVAR

IVAR ECOCOND

Very high-efficiency AISI 316L stainless steel condensing boilers for low temperatures

Heating capacity
110 – 641 kW
Energy
Natural gas, LPG, diesel oil
Efficiency
95.2 to 98.1%
IVAR ASB / ASA

IVAR

IVAR ASB / ASA

Superheated water generator with 3 flue gas passes

Heating capacity
140 – 2,907 kW
Energy
Natural gas, LPG, diesel oil
Efficiency
90 %
IVAR ODE/C

IVAR

IVAR ODE/C

Thermal oil boilers for high-temperature processes

Heating capacity
116 – 5,815 kW
Energy
Natural gas, LPG, diesel oil
Efficiency
87 %