Skip to content

IVAR · Boilers and steam generators

IVAR SupeRAC

6 bar monobloc hot water boilers with flame reversal chamber and high efficiency

Heating capacity
94 – 4,150 kW
Efficiency
91 - 93%
Energy
Natural gas, LPG, diesel oil, biogas
Ask an engineer
IVAR SupeRAC

Technical data

Key data

Heating capacity
94 – 4,150 kW
Energy
Natural gas, LPG, diesel oil, biogas
Output temperature
Up to 110 ºC
Efficiency
91 - 93%

Main advantages

  • High thermal efficiency
  • 6 bar working pressure
  • Robust monobloc construction

Models

IVAR SupeRAC models

Technical data from the manufacturer's data sheet.

SupeRAC (93-1045)

SupeRAC (93-1045)
Model Unit 931051501902302903454054655205806958109301045
PERFORMANCE AND HEAT OUTPUTS
Nominal useful output (kW) kW 93 104.7 151.2 192 233 291 349 407 465 523 581 700 820 940 1,060
Nominal useful output (kcal/h x1000) kcal/h x1000 80 90 130 165 200 250 300 350 400 450 500 602 705 808 911
Furnace heat input (kW) kW 103 115.5 167 211 257 320 384 449 511 577 637 771 899 1,027 1,156
Furnace heat input (kcal/h x1000) kcal/h x1000 88.6 99.3 143.6 181.5 220.6 275 330.2 386.1 439 494 548 663 773 884 994
HYDRAULIC AND COMBUSTION PARAMETERS
Furnace back pressure mbar 0.5 0.7 1.2 1.2 1.5 2.3 3.3 4.4 3.3 4.3 4.8 4.5 5.6 5.4 6
Water-side pressure drop (Δt 15°C) mbar 4.5 5.6 11.8 6.9 10 16.3 23 31 18 22 28 18 25 33 40
Water capacity dm³ (L) 119 119 155 228 228 285 276 329 402 402 476 697 795 733 817
Maximum standard pressure (8-10 bar on request) bar 5 5 5 6 6 6 6 6 6 6 6 6 6 6 6
PHYSICAL DIMENSIONS
Overall outside width (A) mm 790 790 790 940 940 940 940 940 1,040 1,040 1,040 1,240 1,240 1,240 1,240
Overall outside length (B) mm 1,110 1,110 1,360 1,405 1,405 1,655 1,655 1,905 1,990 1,990 2,290 2,345 2,545 2,545 2,795
Overall height (H) mm 880 880 880 990 990 990 990 990 1,150 1,150 1,150 1,280 1,280 1,280 1,280
Body width (A1) mm 750 750 750 900 900 900 900 900 1,000 1,000 1,000 1,200 1,200 1,200 1,200
Body length (B1) mm 760 760 1,010 1,010 1,010 1,260 1,260 1,510 1,512 1,512 1,812 1,814 2,014 2,014 2,264
Height to flue axis (d) mm 460 460 460 510 510 510 510 510 595 595 595 640 640 640 640
Front to return connection distance (e) mm 430 430 430 465 465 465 465 465 625 625 625 625 625 625 625
Distance between flow and return (f) mm 260 260 510 450 450 700 700 950 792 792 1,092 974 1,174 1,174 1,424
CONNECTIONS AND WEIGHT
Flow / return connections (r / f) DN / inch 2" 2" 2" DN 65 DN 65 DN 65 DN 65 DN 65 DN 80 DN 80 DN 80 DN 100 DN 100 DN 100 DN 100
Expansion vessel connection (v) DN / inch 1"1/4 1"1/4 1"1/4 1"1/2 1"1/2 1"1/2 1"1/2 1"1/2 2" 2" 2" DN 65 DN 65 DN 65 DN 65
Drain connection (s) in 3/4"
Flue outlet diameter (Ø) mm 200 200 200 220 220 220 220 220 250 250 250 350 350 350 350
Empty weight kg 250 270 310 460 480 540 550 610 870 890 940 1,310 1,380 1,440 1,620

SupeRAC (1220-4070)

SupeRAC (1220-4070)
Model Unit 12201450186021002330291034904070
PERFORMANCE AND HEAT OUTPUTS
Nominal useful output (kW) kW 1,240 1,480 1,890 2,100 2,360 2,960 3,550 4,150
Nominal useful output (kcal/h x1000) kcal/h x1000 1,066 1,273 1,625 1,806 2,030 2,545 3,053 3,569
Furnace heat input (kW) kW 1,349 1,606 2,056 2,282 2,570 3,213 3,855 4,497
Furnace heat input (kcal/h x1000) kcal/h x1000 1,160 1,381 1,768 1,963 2,210 2,762 3,315 3,867
HYDRAULIC AND COMBUSTION PARAMETERS
Furnace back pressure mbar 6.5 6.8 7 7.2 7.2 7.5 7.8 9
Water-side pressure drop (Δt 15°C) mbar 36 54 45 68 70 64 90 120
Water capacity dm³ (L) 1,277 1,372 2,010 2,204 2,163 3,155 3,292 4,839
Maximum standard pressure (8-10 bar on request) bar 6
PHYSICAL DIMENSIONS
Overall outside width (A) mm 1,380 1,380 1,610 1,610 1,610 1,800 1,800 2,000
Overall outside length (B) mm 2,950 3,200 3,245 3,535 3,535 3,955 4,255 4,790
Overall height (H) mm 1,500 1,500 1,800 1,800 1,800 2,000 2,000 2,210
Body width (A1) mm 1,380 1,380 1,610 1,610 1,610 1,800 1,800 2,000
Body length (B1) mm 2,416 2,666 2,680 2,970 2,970 3,320 3,620 4,024
Height to flue axis (d) mm 810 810 965 965 965 1,070 1,070 1,700
Front to return connection distance (e) mm 430 430 430 430 430 510 510 522
Distance between flow and return (f) mm 1,700 1,950 1,440 1,730 1,730 1,700 2,000 2,200
CONNECTIONS AND WEIGHT
Flow / return connections (r / f) DN DN 125 DN 125 DN 150 DN 150 DN 150 DN 200 DN 200 DN 200
Expansion vessel connection (v) DN DN 80 DN 80 DN 100 DN 100 DN 100 DN 125 DN 125 DN 125
Drain connection (s) in 1"1/2
Flue outlet diameter (Ø) mm 400 400 450 450 450 500 500 600
Empty weight kg 2,200 2,580 3,300 3,640 3,710 5,140 5,840 7,490

Downloads

Catalogues and data sheets

Is the IVAR SupeRAC range right for your project?

We'll help you choose the model and send you the technical documentation and a proposal.

Boilers and steam generators

Other ranges in this family

IVAR SupeRAC 2F

IVAR

IVAR SupeRAC 2F

6 bar hot water boilers with twin stacked furnaces for wide modulation and redundancy

Heating capacity
186 – 814 kW
Energy
Natural gas, LPG, diesel oil, biogas
Efficiency
91 - 93%
IVAR SupeRAC AR

IVAR

IVAR SupeRAC AR

High-efficiency hot water boilers with 3 flue gas passes and low NOx

Heating capacity
81 – 3,610 kW
Energy
Natural gas, LPG, diesel oil, biogas
Efficiency
96.8 to 98.0%
IVAR ECOCOND

IVAR

IVAR ECOCOND

Very high-efficiency AISI 316L stainless steel condensing boilers for low temperatures

Heating capacity
110 – 641 kW
Energy
Natural gas, LPG, diesel oil
Efficiency
95.2 to 98.1%
IVAR TRINOX

IVAR

IVAR TRINOX

Large industrial boilers with 3 true flue gas passes and low NOx

Heating capacity
1,165 – 10,560 kW
Energy
Natural gas, LPG, diesel oil
Efficiency
94 %
IVAR ASB / ASA

IVAR

IVAR ASB / ASA

Superheated water generator with 3 flue gas passes

Heating capacity
140 – 2,907 kW
Energy
Natural gas, LPG, diesel oil
Efficiency
90 %
IVAR ODE/C

IVAR

IVAR ODE/C

Thermal oil boilers for high-temperature processes

Heating capacity
116 – 5,815 kW
Energy
Natural gas, LPG, diesel oil
Efficiency
87 %

Be the first to know

Sign up for the latest news, exclusives and offers from Absorsistem

To download the document, please enter your email address.

Thank you! Your download has started.

Something went wrong. Please try again later.

Please check the highlighted fields.