Skip to content

Enerblue · Air-source heat pumps with natural refrigerant

Enerblue PALLADIUM DWS

Heat pumps with priority high-temperature DHW production up to 70 ºC

Cooling capacity
40 – 135 kW
Heating capacity
50 – 164 kW
Efficiency
COP: 3.20 to 3.60
EER: 2.60 to 3.00
Energy
Electricity (air-source)
Ask an engineer
Enerblue PALLADIUM DWS

Technical data

Key data

Cooling capacity
40 – 135 kW
Heating capacity
50 – 164 kW
Rating conditions
Heating A7;W35 · Cooling A35;W7
Energy
Electricity (air-source)
Output temperature
Maximum water temperature: 70 ºC
Refrigerant
R290 (propane)
Efficiency
COP: 3.20 to 3.60
EER: 2.60 to 3.00
Energy class
A++

Main advantages

  • DWS module for automatic, priority DHW management at 70 °C via a 3-way valve
  • Designed for hospitals, hotels and care homes with a high, continuous DHW demand
  • Ultra-quiet, low-noise technology
  • Full reversibility without interrupting DHW heat production

Models

Enerblue PALLADIUM DWS models

Technical data from the manufacturer's data sheet.

Enerblue PALLADIUM DWS
Model Unit 50.260.275.285.2100.4120.4150.4170.4
HEATING (EN14511 VALUES) (A7;W35)
Nominal heat output (1), (7) kW 50.2 61.4 75 81.9 101 123 151 164
Total power input in heating (1), (7) kW 12.4 14.4 17.6 19.8 24.5 28.8 34.6 39.7
COP (1), (7) 4.05 4.26 4.26 4.14 4.12 4.27 4.36 4.13
HEATING (EN14511 VALUES) (A7;W55)
Nominal heat output (2), (7) kW 47.2 57.3 69.4 76.4 94.5 114 139 153
Total power input in heating (2), (7) kW 16.5 19 23.1 25.6 32.7 38 45.5 51.2
COP (2), (7) 2.86 3.02 3 2.98 2.89 3 3.05 2.99
SEASONAL ENERGY EFFICIENCY INDEX
SCOP (8) 3.13 3.41 3.13 3.24 3.31 3.58 3.31 3.39
Seasonal energy efficiency (ηs) (8) % 122 134 122 127 129 140 130 133
Seasonal efficiency class (8) A+ A++ A+ A++ A++ (9) A++ (9) A++ (9) A++ (9)
COOLING (EN14511 VALUES) (A35;W7)
Nominal cooling capacity (3), (7) kW 40 47.4 61.1 67.1 80.4 93.9 122 135
Total power input in cooling (3), (7) kW 15.6 18.7 21 24.7 31.1 37.1 41.7 49.5
EER (3), (7) 2.56 2.53 2.91 2.72 2.59 2.53 2.93 2.73
DWS + COOLING (EN14511 VALUES) (W55;W7)
DWS nominal heat output (10) kW 53.6 64.5 76.9 88.5 108 130 155 177
Nominal cooling capacity (10) kW 37 45.3 53.5 62.3 74.9 90.9 109 124
Total power input (10) kW 16.7 19.3 23.5 26.4 33.1 38.7 46.1 52.7
TER (Total Efficiency Ratio) (10) 5.43 5.69 5.55 5.71 5.53 5.71 5.73 5.71
COMPRESSOR
Compressor type Scroll
No. of compressors / refrigerant circuits No. / No. 2 / 1 2 / 1 2 / 1 2 / 1 4 / 2 4 / 2 4 / 2 4 / 2
Capacity steps No. 2 2 2 2 4 4 4 4
Oil charge per circuit kg 6.5
Refrigerant charge per circuit (R290) kg 4 5 6.1 7.7 3.8 4.8 5.9 7.5
AXIAL FANS
No. of fans No. 1 1 2 2 2 2 4 4
Air flow m³/h 13,825 13,488 27,602 26,642 27,644 26,985 55,215 53,292
USER-SIDE HEAT EXCHANGER
Heat exchanger type Brazed plate
Water flow (A7/W35) (1) m³/h 9 11 13 14 17 21 26 28
Pressure drop (A7/W35) (1) kPa 29 21 25 14 20 18 23 23
  • Notes and reference conditions (Enerblue PALLADIUM DWS technical catalogue - p. 12):
  • (1) Outdoor air temperature 7 °C DB, 6 °C WB; condenser water inlet-outlet temperature 30-35 °C.
  • (2) Outdoor air temperature 7 °C DB, 6 °C WB; condenser water inlet-outlet temperature 47-55 °C.
  • (3) Outdoor air temperature 35 °C; evaporator water inlet-outlet temperature 12-7 °C.
  • (4) Sound power levels calculated in accordance with ISO 3744.
  • (5) Sound pressure levels at 1 m from the unit in free field.
  • (6) Sound levels at chiller operating conditions, water 12°/7 °C, outdoor air 35 °C.
  • (7) Values in accordance with EN 14511-3:2018.
  • (8) In accordance with European Directive No 813/2013 and EN14511-EN14825 for an average climate (Strasbourg). User application: medium temperature (55 °C), variable outlet temperature.
  • (9) Not subject to EU Regulation No 811/2013, rated heat output > 70 kW.
  • (10) Evaporator water inlet/outlet temperature 12-7 °C, condenser water inlet/outlet temperature 47-55 °C (DWS + cooling mode).

Downloads

Catalogues and data sheets

Is the Enerblue PALLADIUM DWS range right for your project?

We'll help you choose the model and send you the technical documentation and a proposal.

Air-source heat pumps with natural refrigerant

Other ranges in this family

Enerblue PALLADIUM

Enerblue

Enerblue PALLADIUM

High-temperature reversible air-to-water heat pumps with R290 and an ultra-low sound level

Cooling capacity
40 – 135 kW
Heating capacity
50 – 164 kW
Energy
Electricity (air-source)
Efficiency
COP: 3.20 to 3.60
EER: 2.60 to 3.00
Enerblue PALLADIUM 4P

Enerblue

Enerblue PALLADIUM 4P

4-pipe multifunction heat pumps for simultaneous cooling and heating

Cooling capacity
42.4 – 143 kW
Heating capacity
50.2 – 164 kW
Energy
Electricity (air-source)
Efficiency
COP: 3.20 to 3.60
Enerblue PURPLE HP

Enerblue

Enerblue PURPLE HP

High-efficiency reversible air-to-water heat pumps with semi-hermetic reciprocating compressors

Cooling capacity
22 – 181 kW
Heating capacity
26 – 222 kW
Energy
Electricity (air-source)
Efficiency
SCOP: 3.33 to 4.60
SEER: 3.31 to 4.33
Enerblue PURPLEi HP

Enerblue

Enerblue PURPLEi HP

Modulating reversible air-to-water heat pumps with inverter technology and R290

Cooling capacity
22 – 181 kW
Heating capacity
26 – 221 kW
Energy
Electricity (air-source)
Efficiency
SCOP: 3.33 to 4.38
SEER: 3.12 to 4.21
Enerblue LITHIUM

Enerblue

Enerblue LITHIUM

Large industrial-capacity reversible heat pumps with axial fans and R290

Cooling capacity
177 – 303 kW
Heating capacity
208 – 361 kW
Energy
Electricity (air-source)
Efficiency
SCOP: 3.15 to 3.40
SEER: 3.46 to 4.01

Be the first to know

Sign up for the latest news, exclusives and offers from Absorsistem

To download the document, please enter your email address.

Thank you! Your download has started.

Something went wrong. Please try again later.

Please check the highlighted fields.