Aisin · Gas heat pumps

Aisin GEHP F series

Gas engine-driven compression heat pumps with a Toyota engine, for VRF or hydronic (AWS) systems

Cooling capacity
42.5 – 170 kW
Heating capacity
50 – 190 kW
Efficiency
SPER heating 1.55
SPER cooling 2.44
Energy
Natural gas or LPG
Ask an engineer

Technical data

Key data

Cooling capacity
42.5 – 170 kW
Heating capacity
50 – 190 kW
Rating conditions
Heating A7W35 · Cooling A35W7
Energy
Natural gas or LPG
Output temperature
Chilled water at 7 ºC.
Hot water up to 50 ºC.
DHW 70 ºC
Refrigerant
R-410A
Efficiency
SPER heating 1.55
SPER cooling 2.44
Energy class
A++

Main advantages

  • Minimal electricity consumption
  • DHW from the heat recovered from the engine
  • Less dependence on the electricity grid
  • Toyota reliability

Models

Aisin GEHP F series models

Technical data from the manufacturer's data sheet.

GEHP VRV

GEHP VRV
Model Unit AWGP450F1 (16 HP)AWGP560F1 (20 HP)AWGP710F1 (25 HP)AWGP850F1 (30 HP)450+450 (16+16 HP)450+560 (16+20 HP)560+560 (20+20 HP)560+710 (20+25 HP)710+710 (25+25 HP)710+850 (25+30 HP)850+850 (30+30 HP)
COOLING PERFORMANCE
Nominal cooling capacity kW 45 56 71 85 90 101 112 127 142 156 170
Nominal consumption, cooling mode kW 31.4 38.9 54.4 71.2 62.8 70.3 77.8 93.3 108.8 125.6 142.2
G.U.E. cooling mode 1.43 1.44 1.31 1.19 1.43 1.44 1.44 1.36 1.31 1.24 1.19
SPER cooling mode (seasonal efficiency) 2.39 2.44 2.42 2.17 2.39 2.44 2.44 2.43 2.42 2.3 2.17
HEATING AND HEAT RECOVERY PERFORMANCE
Nominal heating capacity kW 50 63 80 95 100 113 126 143 160 175 190
Nominal consumption, heating mode kW 29.8 38.1 53.9 68 106 120 134 151 168 179 190
Maximum heating output (29°C) kW 53 67 84 95 59.6 67.9 76.2 92 107.8 121.9 136
Maximum heating consumption (29°C) kW 40.1 79.6 56.9 86.8 80.2 97 113.8 136.5 159.2 166.4 173.6
G.U.E. heating mode 1.68 1.65 1.48 1.4 1.68 1.66 1.65 1.55 1.48 1.44 1.39
SPER heating mode (class A++) 1.48 1.55 1.54 1.52 1.48 1.52 1.55 1.54 1.54 1.53 1.52
Maximum heat recovery (free DHW) kW 15.7 27.2 19.5 35.6 31.4 35.6 39 46.7 54.4 62.8 71.2
ELECTRICAL DATA AND COMPONENTS
Power supply V / Hz Single-phase 220V - 50 Hz
Rated current A 20 20 20 20 40 40 40 40 40 40 40
Electrical power input (min/max) kW 0.50/0.64 0.74/1.19 0.62/0.91 1.12/1.49 1.00/1.28 1.24/1.83 1.48/2.38 1.36/2.10 1.24/1.82 1.74/2.40 2.24/2.98
Compressor type Variable-capacity scroll x 2 Variable-capacity scroll x 2 Variable-capacity scroll x 2 Variable-capacity scroll x 3 2x (Scroll x 2) 2x (Scroll x 2) 2x (Scroll x 2) 2x (Scroll x 2) 2x (Scroll x 2) Scroll x2 + Scroll x3 2x (Scroll x 3)
Refrigerant / charge per unit R410A - 11.5 kg R410A - 11.5 kg R410A - 11.5 kg R410A - 11.5 kg R410A - 2x 11.5 kg R410A - 2x 11.5 kg R410A - 2x 11.5 kg R410A - 2x 11.5 kg R410A - 2x 11.5 kg R410A - 2x 11.5 kg R410A - 2x 11.5 kg
ACOUSTICS, DIMENSIONS AND WEIGHTS
Sound pressure dB(A) 58 59 62 65 61 62 62 64 65 67 68
Sound power dB 75 76 82 86 78 79 79 84 85 88 89
Outside dimensions (H x L x D) mm 2245 x 1660 x 880 2245 x 1660 x 880 2245 x 1660 x 880 2245 x 1660 x 880 2x (2245 x 1660 x 880) 2x (2245 x 1660 x 880) 2x (2245 x 1660 x 880) 2x (2245 x 1660 x 880) 2x (2245 x 1660 x 880) 2x (2245 x 1660 x 880) 2x (2245 x 1660 x 880)
Total unit weight kg 765 795 870 870 1,530 1,560 1,590 1,665 1,740 1,740 1,740
Maximum number of connectable indoor units units 26 41 33 50 63 63 63 63 63 63 63
Preventive maintenance interval h 10,000
Engine oil change interval h 30,000

GEHP + AWS

GEHP + AWS
Model Unit AWS 16HP-F1(J)AWS 20HP-F1(J)AWS 25HP-F1(J)AWS 30HP-F1(J)AWS 40HP TWIN (16+16)AWS TWIN (16+20)AWS 50HP TWIN (16+25)AWS TWIN (20+20)AWS TWIN (20+25)AWS 50HP TWIN (25+25)AWS 60HP TWIN (30+30)
COOLING PERFORMANCE (CHILLED WATER)
Nominal cooling capacity kW 42.5 53 63.5 74.5 85 95.5 106 106 116.5 127 149
Nominal consumption, cooling mode kW 30 43 56 70.7 60 73 99 86 86 112 141.4
G.U.E. cooling mode 1.13 1.23 1.42 1.05 1.42 1.31 1.17 1.24 1.23 1.13 1.05
SPER cooling mode (seasonal efficiency) 1.89 1.89 1.87 1.91 1.89 1.89 1.89 1.88 1.88 1.87 1.91
Minimum water outlet temperature °C 7
HEATING AND HEAT RECOVERY PERFORMANCE (HOT WATER)
Nominal heating capacity kW 50 62.5 77 87.5 100 112.5 127 125 139.5 154 175
Nominal consumption, heating mode kW 34 42.5 54.2 61.5 68 76.5 96.7 88.2 85 108.4 123
Maximum heating output kW 68 77 53.5 91 107 121.5 136 130.5 145 154 182
Maximum heating consumption kW 37.3 53.2 58.5 75.7 74.6 90.5 106.4 111.7 95.8 117 151.4
G.U.E. heating mode 1.47 1.47 1.42 1.42 1.47 1.47 1.47 1.44 1.44 1.42 1.42
SPER heating mode (class A++) 1.57 1.55 1.54 1.51 1.57 1.56 1.55 1.55 1.54 1.54 1.53
Maximum heat recovery (free DHW) kW 19.5 23.5 30.5 44.5 39 43 50 54 47 61 89
Maximum water outlet temperature °C 50
HYDRAULIC CIRCUIT AND MODULATION
Nominal water flow m³/h 10 12 8 14 20 22 24 24 26 28 32
Output modulation % 35-100 28-100 23-100 22-100 20-100 20-100 20-100 20-100 20-100 20-100 20-100
Hydraulic pipe diameter DN 40 DN 40 DN 40 DN 40 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2"
Internal heat exchanger pressure drop mca 3.3 4.6 2.2 4.8 3.3 4.6 4.8 4.6 4.6 4.8 4.8
ELECTRICAL DATA AND MODULE
Module power supply V / Ph / Hz 220V / Single-phase / 50 Hz
Electrical power input (with pump) W 550 770 700 900 1,100 1,320 1,400 1,400 1,470 1,600 1,800
Electrical power input (without pump) W 190 190 190 190 200 200 200 200 200 200 200
Rated current (without pump) A 1 1 1 1 2 2 2 2 2 2 2
AWS MODULE DIMENSIONS AND WEIGHTS
AWS module dimensions (H x L x D) mm 915 x 710 x 1020
AWS module weight (with pump / without pump) kg 204/177 204/177 207/180 207/180 236 236 236 236 236 236 236
Connectable gas heat pump units units 1 1 1 1 2 2 2 2 2 2 2

Downloads

Catalogues and data sheets

Is the Aisin GEHP F series range right for your project?

We'll help you choose the model and send you the technical documentation and a proposal.

Gas heat pumps

Other ranges in this family

Robur GAHP A Plus

Robur

Robur GAHP A Plus

Air-source gas absorption heat pumps for heating and DHW

Heating capacity
44.6 kW
Energy
Natural gas or LPG + air
Efficiency
GUE 172 %
Energy class
A+ (A++ low-noise version)
Robur GAHP AR Plus

Robur

Robur GAHP AR Plus

Reversible gas absorption heat pumps: heating, cooling and DHW

Cooling capacity
16.9 kW
Heating capacity
38.8 kW
Energy
Natural gas or LPG + air
Efficiency
GUE 154 % (heating) · 67 % (cooling)
Robur GAHP GS Plus

Robur

Robur GAHP GS Plus

Ground-source gas absorption heat pumps

Heating capacity
43.0 kW
Energy
Natural gas or LPG + ground
Efficiency
GUE 165 %
Energy class
A++
Robur GAHP WS Plus

Robur

Robur GAHP WS Plus

Water-source gas absorption heat pumps

Heating capacity
45.3 kW
Energy
Natural gas or LPG + water
Efficiency
GUE 174 %
Energy class
A++
Robur LINK

Robur

Robur LINK

Prefabricated thermal plants combining heat pumps, chillers and boilers

Cooling capacity
16.9 – 88.5 kW
Heating capacity
21.0 – 225 kW
Energy
Natural gas or LPG
Efficiency
Depending on configuration

Be the first to know

Sign up for the latest news, exclusives and offers from Absorsistem

To download the document, please enter your email address.

Thank you! Your download has started.

Something went wrong. Please try again later.

Please check the highlighted fields.