Oilon
Oilon ChillHeat P Series
High-temperature water-to-water heat pumps up to 120 ºC
- Heating capacity
- 30 – 1,000 kW
- Energy
- Electricity and waste heat
- Efficiency
- High COP even at very low part load (COP of 2 to 7 depending on the application)
Oilon · High-temperature heat pumps
Industrial water-to-water heat pumps up to 85 ºC
Technical data
Models
Technical data from the manufacturer's data sheet.
| Model | Unit | S180 | S280 | S380 | S490 | S580 |
|---|---|---|---|---|---|---|
| GENERAL DATA AND CONFIGURATION | ||||||
| Compressor type and number | Screw, 1 | |||||
| Number of refrigerant circuits | 1 | |||||
| Heat exchanger types | Plate heat exchangers | |||||
| Variable frequency drive (VFD / inverter) | Standard (S180-S580) | |||||
| Maximum water/heat output temperature | °C | 85 | ||||
| Minimum water/cooling output temperature | °C | -10 | ||||
| PERMITTED REFRIGERANTS AND COMPATIBILITY | ||||||
| HFC refrigerant R-134a (GWP 1430 | A1 | max 80°C) | Yes | |||||
| HFO/HFC refrigerant R-513A (GWP 629 | A1 | max 80°C) | Yes | |||||
| HFO/HFC refrigerant R-450A (GWP 601 | A1 | max 88°C) | Yes | |||||
| HFO/HFC refrigerant R-515B (GWP 288 | A1 | max 95°C / 85°C) | Yes | |||||
| HFO refrigerant R-1234ze(E) (GWP 1.37 | A2L | max 95°C / 85°C) | Yes | |||||
| ELECTRICAL DATA | ||||||
| Power supply | V / Hz | 3/N/PE 400V 50Hz | ||||
| Recommended fuse rating (most demanding condition) | A | 250A | 355A | 500A | 630A | 800A |
| DIMENSIONS AND WEIGHTS | ||||||
| Height | mm | 2286 – 2306 | 2266 – 2286 | 2208 – 2228 | 2476 – 2496 | 2476 – 2496 |
| Length | mm | 3,124 | 3,124 | 3,124 | 3,312 | 3,312 |
| Width | mm | 945 | ||||
| Total unit weight | kg | 2,300 | 2,900 | 3,600 | 4,000 | 4,500 |
| Model | Unit | S600 | S800 | S1000 | S1200 | S1500 | S2000 |
|---|---|---|---|---|---|---|---|
| GENERAL DATA AND CONFIGURATION | |||||||
| Compressor type and number | Screw, 2 | ||||||
| Number of refrigerant circuits | 2 | ||||||
| Heat exchanger types | Shell and tube | ||||||
| Variable frequency drive (VFD / inverter) | Standard | Standard | Standard | Standard | Optional | Optional | |
| Maximum water/heat output temperature (standard / version B) | °C | 85 / 90 (B) | 85 / 90 (B) | 85 / 90 (B) | 85 | 85 | 85 |
| Minimum water/cooling output temperature | °C | -10 | |||||
| PERMITTED REFRIGERANTS AND COMPATIBILITY | |||||||
| HFC refrigerant R-134a (GWP 1430 | A1 | max 80°C) | Yes | ||||||
| HFO/HFC refrigerant R-513A (GWP 629 | A1 | max 80°C) | Yes | ||||||
| HFO/HFC refrigerant R-450A (GWP 601 | A1 | max 88°C) | Yes | ||||||
| HFO/HFC refrigerant R-515B (GWP 288 | A1 | max 95°C / 85°C) | Yes | ||||||
| HFO refrigerant R-1234ze(E) (GWP 1.37 | A2L | max 95°C / 85°C) | Yes | ||||||
| ELECTRICAL DATA | |||||||
| Power supply | V / Hz | 3/N/PE 400V 50Hz | |||||
| Recommended fuse rating (most demanding condition) | A | 2x 400A | 2x 500A | 2x 630A | 2x 800A | 2x 800A | 2x 1250A |
Downloads
We'll help you choose the model and send you the technical documentation and a proposal.
High-temperature heat pumps
Oilon
High-temperature water-to-water heat pumps up to 120 ºC
Enerblue
High-temperature reversible air-to-water heat pumps with reciprocating compressors and R513A