Skip to content

Thermax · Absorption chillers

Thermax TAC E2

Exhaust gas-driven double-effect absorption chillers

Cooling capacity
432 – 8,115 kW
Efficiency
COP: 1.3 to 1.5
Energy
Exhaust gas
Ask an engineer
Thermax TAC E2

Technical data

Key data

Cooling capacity
432 – 8,115 kW
Rating conditions
CHW 12/7 ºC
CW 32/37 ºC
Energy
Exhaust gas
Output temperature
Chilled water at 7 ºC
Refrigerant
Water (H2O)
Efficiency
COP: 1.3 to 1.5

Main advantages

  • Exhaust gas heat recovery
  • High double-effect efficiency: COP of up to 1.6
  • Maximum heat recovery: cools the gases down to 130 ºC
  • Minimal electricity consumption
  • Wide cooling capacity range

Models

Thermax TAC E2 models

Technical data from the manufacturer's data sheet.

TAC E2
Model Unit E2 C3E2 C4E2 D1E2 D2E2 D3E2 D4E2 E1E2 E2E2 E3E2 E4E2 E5E2 E6E2 F1E2 F2E2 F3E2 G1E2 G2E2 G3E2 G4E2 G5E2 G6E2 H1E2 H2E2 J1E2 J2
GENERAL DATA
Version / application Exhaust gas-fired absorption chiller
Installation location Indoor
Refrigerant / absorbent Water (R718) / Lithium bromide (LiBr)
Chilled water inlet / outlet temperature °C 12.0 / 6.0
Maximum allowable pressure, chilled water circuit bar(g) 8
Cooling water inlet temperature (tower) °C 27.0
Maximum allowable pressure, cooling water circuit bar(g) 8
CAPACITY AND HYDRAULIC CIRCUITS
Nominal cooling capacity kW 432 541 686 809 1,020 1,146 1,364 1,540 1,762 1,906 2,096 2,331 2,440 2,535 2,816 3,210 3,600 3,977 4,314 5,186 5,587 5,981 6,772 7,176 8,115
Nominal cooling capacity (reference) TR 123 154 195 230 290 326 388 438 501 542 596 663 694 721 801 913 1,024 1,131 1,227 1,475 1,589 1,701 1,926 2,041 2,308
Chilled water flow m³/h 61.4 77.1 97.8 115.7 145.7 163.6 195 220 251.4 272.2 299.3 332.9 348.6 362.2 402.2 458.6 514.3 567.9 616.3 740.7 797.9 854.3 967.2 1,025 1,159.3
Cooling water flow (tower) m³/h 104 131 165 195 245 275 330 371 425 460 505 562 590 615 680 775 870 961 1,043 1,254 1,340 1,445 1,640 1,735 1,960
FLUE GAS CIRCUIT (HEAT SOURCE)
Required heat input kW 287 361 457 541 677 759 906 1,025 1,172 1,270 1,395 1,551 1,617 1,694 1,879 2,139 2,393 2,640 2,872 3,426 3,697 3,987 4,513 4,783 5,410
Flue gas inlet temperature range °C 350 – 600
Flue gas outlet temperature °C 170
ELECTRICAL DATA
Total electrical consumption kVA 7.6 7.6 7.6 7.6 9.1 9.1 11.2 11.2 11.2 13.4 13.4 13.4 18.1 18.1 18.1 20.3 20.3 20.3 20.3 25.3 25.3 25.3 25.3 25.3 25.3
Supply voltage / supply conditions V / Hz 415V (±10%), 50Hz (±5%), AC III + neutral
DIMENSIONS AND WEIGHTS
Length (L) mm 2,900 2,900 4,400 4,400 4,400 4,400 5,000 5,100 5,100 5,100 5,100 5,100 6,200 6,200 6,200 7,700 7,700 7,900 7,900 8,200 8,200 9,500 9,500 11,300 11,300
Width (W) mm 2,500 2,500 2,800 2,800 3,100 3,100 3,100 3,400 3,400 3,400 3,700 3,700 3,800 3,800 3,800 3,800 3,800 4,300 4,300 4,800 4,800 4,800 4,800 4,900 4,900
Height (H) mm 2,900 2,900 2,900 2,900 3,000 3,000 3,000 3,400 3,400 3,400 3,600 3,600 3,700 3,700 3,700 3,800 3,800 4,000 4,000 4,300 4,300 4,300 4,300 4,400 4,400
Operating weight kg 8,200 8,500 10,900 11,300 13,500 14,200 15,800 18,700 19,400 19,900 22,700 23,300 29,400 29,900 30,900 34,500 36,100 46,100 46,900 55,900 57,300 66,600 68,200 79,200 81,100

Downloads

Catalogues and data sheets

Is the Thermax TAC E2 range right for your project?

We'll help you choose the model and send you the technical documentation and a proposal.

Absorption chillers

Other ranges in this family

Yazaki WFC-SC

Yazaki

Yazaki WFC-SC

Hot water-driven single-effect absorption chillers

Cooling capacity
17.6 – 176 kW
Energy
Hot water
Efficiency
COP: 0.7
Thermax TAC L1

Thermax

Thermax TAC L1

Hot water-driven single-effect absorption chillers

Cooling capacity
157 – 1,000 kW
Energy
Hot water
Efficiency
COP: 0.7 to 0.8
Thermax TAC L5

Thermax

Thermax TAC L5

Hot water-driven single-effect absorption chillers

Cooling capacity
714 – 5,764 kW
Energy
Hot water
Efficiency
COP: 0.7 to 0.8
Thermax TAC S1

Thermax

Thermax TAC S1

Steam-driven single-effect absorption chillers

Cooling capacity
404 – 7,385 kW
Energy
Steam
Efficiency
COP: 0.7 to 0.8
Thermax TAC S2

Thermax

Thermax TAC S2

Steam-driven double-effect absorption chillers

Cooling capacity
400 – 7,410 kW
Energy
Steam
Efficiency
COP: 1.3 to 1.5
Thermax TAC G2

Thermax

Thermax TAC G2

Gas-fired double-effect absorption chillers

Cooling capacity
401 – 4,969 kW
Energy
Natural gas or LPG
Efficiency
COP: 1.3 to 1.5

Be the first to know

Sign up for the latest news, exclusives and offers from Absorsistem

To download the document, please enter your email address.

Thank you! Your download has started.

Something went wrong. Please try again later.

Please check the highlighted fields.